82
1 SERVO PARAMETER DETAILS
1.5 I/O setting servo parameters group ([Pr. PD_ _ ])
[Pr. PD15_Driver communication setting (*IDCS)]
[Pr. PD15.0_Master axis operation selection]
0: Disabled (master-slave operation function is not used)
1: Enabled (set this servo amplifier for the master axis)
To set the servo amplifier for the slave axis, set "0".
[Pr. PD15.1_Slave axis operation selection]
0: Disabled (master-slave operation function is not used)
1: Enabled (set this servo amplifier for the slave axis)
To set the servo amplifier for the master axis, set "0".
[Pr. PD16_Driver communication setting - Master - Transmit data
selection 1 (*MD1)]
Select the data to send from the master axis to the slave axis.
Set this servo parameter to "00000038 (torque command)" when setting the servo amplifier as the master axis (when [Pr.
PD15.0] is set to "1").
This servo parameter setting is disabled when the servo amplifier is set as the slave axis (when [Pr. PD15.0] is set to "0").
[Pr. PD17_Driver communication setting - Master - Transmit data
selection 2 (*MD2)]
Select the data to send from the master axis to the slave axis.
Set this servo parameter to "0000003A (speed limit command)" when setting the servo amplifier as the master axis (when [Pr.
PD15.0] is set to "1").
This servo parameter setting is disabled when the servo amplifier is set as the slave axis (when [Pr. PD15.0] is set to "0").
[Pr. PD20_Driver communication setting - Slave - Master axis No.
selection 1 (*SLA1)]
Set the axis number of the servo amplifier for the corresponding master axis of the slave axis.
This servo parameter is enabled when the servo amplifier is set as the slave axis (when [Pr. PD15.1] is set to "1"). For axis
numbers, refer to "Switches" in the User's Manual (Introduction).
When the setting value of this servo parameter is "0", the setting is disabled.
Initial value
Setting range
Setting method
Ver.
00000000h
00000000h to 00000011h
Each axis
Refer to the relevant detail No.
Initial value
Setting range
Ver.
0h
0h to 1h
C4
Initial value
Setting range
Ver.
0h
0h to 1h
C4
Initial value
Setting range
Setting method
Ver.
00000000h
00000000h to 0000FFFFh
Each axis
C4
Initial value
Setting range
Setting method
Ver.
00000000h
00000000h to 0000FFFFh
Each axis
C4
Initial value
Setting range
Setting method
Ver.
0
0 to 32
Each axis
C4