126
1 SERVO PARAMETER DETAILS
1.8 Motor extension setting servo parameters group ([Pr. PL_ _ ])
[Pr. PL18_Magnetic pole detection - Minute position detection
method - Identification signal amplitude (IDLV)]
Set an identification signal amplitude to be used in the minute position detection method.
This servo parameter is enabled when [Pr. PL08.0 Magnetic pole detection method selection] is set to "4".
When the setting value of this servo parameter is "0", the amplitude will be 100 [%].
Initial value
Setting range
Setting method
Ver.
0 [%]
0 to 200
Each axis
C4