1 SERVO PARAMETER DETAILS
1.7 Extension setting 3 servo parameters group ([Pr. PF_ _ ])
[Pr. PF88_Drive recorder - Analog channel setting 2 (DRAC2)]
[Pr. PF88.0-2_Drive recorder - Analog channel 3 selection]
Select the analog channel 3 of the drive recorder.
The servo parameter is disabled in the following conditions.
• [Pr. PF80.0 Drive recorder - Operation mode selection] is set to "0" (automatic setting mode)
Refer to the following for values that can be assigned.
Page 112 [Pr. PF87.0-2_Drive recorder - Analog channel 1 selection]
[Pr. PF88.4-6_Drive recorder - Analog channel 4 selection]
Select the analog channel 4 of the drive recorder.
The servo parameter is disabled in the following conditions.
• [Pr. PF80.0 Drive recorder - Operation mode selection] is set to "0" (automatic setting mode)
Refer to the following for values that can be assigned.
Page 112 [Pr. PF87.0-2_Drive recorder - Analog channel 1 selection]
Initial value
Setting range
Setting method
Ver.
02040003h
Refer to the relevant detail No.
Each axis
Refer to the relevant detail No.
Initial value
Setting range
Ver.
003h
Refer to the text
C4
Initial value
Setting range
Ver.
204h
Refer to the text
C4