124
1 SERVO PARAMETER DETAILS
1.8 Motor extension setting servo parameters group ([Pr. PL_ _ ])
[Pr. PL17_Magnetic pole detection - Minute position detection
method - Function selection (LTSTS)]
This servo parameter is enabled when [Pr. PL08.0 Magnetic pole detection method selection] is set to "4" (minute position
detection method).
[Pr. PL17.0_Response selection]
Select the responsiveness of the minute position detection method.
To make the travel distance at the magnetic pole detection smaller, set a larger value.
Refer to the following table for setting values.
Initial value
Setting range
Setting method
Ver.
00000000h
Refer to the relevant detail No.
Each axis
Refer to the relevant detail No.
Initial value
Setting range
Ver.
0h
Refer to the text
C4
Setting value of [Pr. PL17.0]
Responsiveness
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
Low response
Middle response
High response
Содержание MR-J5-B
Страница 1: ...MR J5 B MR J5W B User s Manual Parameters MR J5 _B_ MR J5W_ _B_ Mitsubishi Electric AC Servo System ...
Страница 2: ......
Страница 153: ...4 SERVO PARAMETER SETTING METHOD 4 2 Controller 151 4 MEMO ...
Страница 157: ......