15 - 27
15. COMMUNICATION FUNCTIONS
15.12.8 Test operation mode
(1) Instructions for test operation mode
The test operation mode must be executed in the following procedure. If communication is interrupted
for longer than 0.5s during test operation, the servo amplifier causes the motor to be decelerated to a
stop and servo-locked. To prevent this, continue communication without a break, e.g. monitor the
status display.
(a) Execution of test operation
1) Turn off all input devices.
2) Disable the input devices.
Command Data
No.
Data
[9][0] [0][0]
1EA5
3) Choose the test operation mode.
Command Data No.
Transmission data
Selection of test operation mode
[8][B]
[0][0]
0000
Test operation mode cancel
[8][B] [0][0]
0001 Jog
operation
[8][B] [0][0]
0002 Positioning
operation
[8][B] [0][0]
0003 Motor-less
operation
[8][B]
[0][0]
0004
DO forced output
4) Set the data needed for test operation.
5) Start.
6) Continue communication using the status display or other command.
(b) Termination of test operation
To terminate the test operation mode, complete the corresponding operation and.
1) Clear the test operation acceleration/deceleration time constant.
Command Data
No.
Data
[A][0] [1][2]
1EA5
2) Cancel the test operation mode.
Command Data
No.
Data
[8][B] [0][0]
0000
3) Enable the disabled input devices.
Command Data
No.
Data
[9][0] [1][0]
1EA5
Содержание MR-J2S-10CP
Страница 11: ...A 10 MEMO ...
Страница 19: ...8 MEMO ...
Страница 45: ...1 26 1 FUNCTIONS AND CONFIGURATION MEMO ...
Страница 181: ...6 20 6 MR Configurator SERVO CONFIGURATION SOFTWARE MEMO ...
Страница 207: ...7 26 7 DISPLAY AND OPERATION MEMO ...
Страница 219: ...8 12 8 GENERAL GAIN ADJUSTMENT MEMO ...
Страница 229: ...9 10 9 SPECIAL ADJUSTMENT FUNCTIONS MEMO ...
Страница 231: ...10 2 10 INSPECTION MEMO ...
Страница 249: ...12 8 12 OUTLINE DIMENSION DRAWINGS MEMO ...
Страница 257: ...13 8 13 CHARACTERISTICS MEMO ...