5 - 2
5. PARAMETERS
5.1.2 List
POINT
The parameters marked * before their symbols are made valid by
switching power off once and then switching it on again after parameter
setting.
Refer to the corresponding reference items for details of the parameters.
(1) Item list
Class No.
Symbol
Name and Function
Initial value
Unit
Customer
setting
0 *STY
Command
system/regenerative
option
selection
0000
1 *FTY
Feeding
function
selection
0000
2
*OP1
Function selection 1
0002
3 ATU
Auto
tuning
0105
4
*CMX Electronic gear numerator
1
5
*CDV
Electronic gear denominator
1
6 INP
In-position
range
100 pulse
7
PG1
Position control gain 1
35
rad/s
8
*ZTY
Home position return type
0010
9
ZRF
Home position return speed
500
r/min
10 CRF
Creep
speed
10 r/min
11
ZST
Home position shift distance
0
m
12 CRP
Rough
match
output
range
0 10
STM
m
13 JOG
Jog
speed
100 r/min
14 *STC
S-pattern
acceleration/deceleration
time
constant
0
ms
15 *SNO
Station
number
setting
0
station
16
*BPS
Communication baud rate selection, alarm history clear
0000
17 MOD
Analog
monitor
output
0100
18 *DMD
Status
display
selection
0000
B
asi
c pa
ra
m
et
ers
19 *BLK
Parameter
write
inhibit
0000
Содержание MR-J2S-10CP
Страница 11: ...A 10 MEMO ...
Страница 19: ...8 MEMO ...
Страница 45: ...1 26 1 FUNCTIONS AND CONFIGURATION MEMO ...
Страница 181: ...6 20 6 MR Configurator SERVO CONFIGURATION SOFTWARE MEMO ...
Страница 207: ...7 26 7 DISPLAY AND OPERATION MEMO ...
Страница 219: ...8 12 8 GENERAL GAIN ADJUSTMENT MEMO ...
Страница 229: ...9 10 9 SPECIAL ADJUSTMENT FUNCTIONS MEMO ...
Страница 231: ...10 2 10 INSPECTION MEMO ...
Страница 249: ...12 8 12 OUTLINE DIMENSION DRAWINGS MEMO ...
Страница 257: ...13 8 13 CHARACTERISTICS MEMO ...