4 - 12
4. OPERATION
4.2.4 Absolute value command/incremental value command specifying system
This system is an auxiliary function for point tables to use them by specifying the absolute value
command and incremental value command.
(1) Point table
Set each value of point tables by using MR Configurator (Setup software) or operation section.
Set to point tables the following, "Position data", "Servo motor speed", "Acceleration time constant",
"Deceleration time constant", "Dwell time" and "Auxiliary function".
To specify the command system, set "Auxiliary function" as shown below.
For absolute value command system, set "0" or "1".
For incremental value command system, set "2" or "3".
Name Setting
range Unit
Description
Position data
999999 to 999999
10
STM
m
(1) When this point table is used in an absolute value command system
Set the target address (absolute value).
This value can also be set using the teaching function. (Refer to section
7.10.)
(2) When this point table is used in an incremental value command system
Set the moving distance. A " " sign indicates a reverse rotation
command.
The teaching function is unusable.
Servo motor
speed
0 to permissible speed
r/min
Set the command speed of the servo motor for execution of positioning.
The setting should be equal to or less than the instantaneous permissible
speed of the servo motor.
Acceleration
time constant
0 to 20000
ms
Set the acceleration time constant.
Set the time until the rated speed of the servo motor is reached.
Deceleration
time constant
0 to 20000
ms
Set the deceleration time constant.
Set the time until the servo motor running at rated speed comes to a stop.
Dwell
0 to 20000
ms
Set the dwell.
Set "0" or "2" in the auxiliary function to make the dwell invalid.
Set "1" or "3" in the auxiliary function and 0 in the dwell to perform
continuous operation.
When the dwell is set, the position command of the selected point table is
completed, and after the set dwell has elapsed, the position command of the
next point table is started.
Auxiliary
function
0 to 3
Set the auxiliary function.
(1) When this point table is used in an absolute value command system
0: Automatic operation is performed in accordance with a single point table
chosen.
1: Operation is performed in accordance with consecutive point tables
without a stop.
(2) When this point table is used in an incremental value command system
2: Automatic operation is performed in accordance with a single point table
chosen.
3: Operation is performed in accordance with consecutive point tables
without a stop.
When a different rotation direction is set, smoothing zero (command
output) is confirmed and the rotation direction is then reversed.
Setting "1" or "3" in point table No.31 results in an error.
For full information, refer to section 4.2.6.
Содержание MR-J2S-10CP
Страница 11: ...A 10 MEMO ...
Страница 19: ...8 MEMO ...
Страница 45: ...1 26 1 FUNCTIONS AND CONFIGURATION MEMO ...
Страница 181: ...6 20 6 MR Configurator SERVO CONFIGURATION SOFTWARE MEMO ...
Страница 207: ...7 26 7 DISPLAY AND OPERATION MEMO ...
Страница 219: ...8 12 8 GENERAL GAIN ADJUSTMENT MEMO ...
Страница 229: ...9 10 9 SPECIAL ADJUSTMENT FUNCTIONS MEMO ...
Страница 231: ...10 2 10 INSPECTION MEMO ...
Страница 249: ...12 8 12 OUTLINE DIMENSION DRAWINGS MEMO ...
Страница 257: ...13 8 13 CHARACTERISTICS MEMO ...