4 - 15
4. OPERATION
4.2.6 Automatic continuous operation
(1) What is automatic continuous operation?
By merely choosing one point table and making a start (ST1 or ST2), operation can be performed in
accordance with the point tables having consecutive numbers.
Automatic operation is available in two types: varied speed operation and automatic continuous
positioning operation.
Either type may be selected as follows.
(a) In absolute value command system or incremental value command system
Point table setting
Dwell Auxiliary
function
0 1
Automatic continuous
operation
Speed changing operation
Automatic continuous
positioning operation
1 or more
1
(b) In absolute value command /incremental value command specifying system
Point table setting
Auxiliary function
Dwell
When position data is
absolute value
When position data is
incremental value
0 1
3
Automatic continuous
operation
Speed changing operation
Automatic continuous
positioning operation
1 or more
1
3
(2) Varied speed operation
Speed during positioning operation can be changed by setting the auxiliary function of the point table.
Use the number of point tables equal to the number of speeds to be set.
By setting "1" to the auxiliary function, operation is performed at the speed set in the next point table
during positioning. The position data valid at this time is the data selected at start and the
acceleration and deceleration time constants of the subsequent point tables are made invalid.
By setting "1" to the auxiliary function of up to point table No.30, operation can be performed at a
maximum of 31 speeds. Set "0" to the auxiliary function of the last point table.
When performing varied speed operation, always set "0" to the dwell. If "1" or more is set, automatic
continuous positioning operation is made valid.
The following table gives a setting example.
Point table No.
Dwell [ms] (Note 1)
Auxiliary function
Variable speed operation
1 0 1
2 0 1
3 0
0
(Note 2)
Consecutive point table data
4 0 1
5 0 1
6 0 1
7 0
0
(Note 2)
Consecutive point table data
Note 1. Always set "0".
2. Always set "0" or "2" to the auxiliary function of the last point table among the consecutive point tables.
Содержание MR-J2S-10CP
Страница 11: ...A 10 MEMO ...
Страница 19: ...8 MEMO ...
Страница 45: ...1 26 1 FUNCTIONS AND CONFIGURATION MEMO ...
Страница 181: ...6 20 6 MR Configurator SERVO CONFIGURATION SOFTWARE MEMO ...
Страница 207: ...7 26 7 DISPLAY AND OPERATION MEMO ...
Страница 219: ...8 12 8 GENERAL GAIN ADJUSTMENT MEMO ...
Страница 229: ...9 10 9 SPECIAL ADJUSTMENT FUNCTIONS MEMO ...
Страница 231: ...10 2 10 INSPECTION MEMO ...
Страница 249: ...12 8 12 OUTLINE DIMENSION DRAWINGS MEMO ...
Страница 257: ...13 8 13 CHARACTERISTICS MEMO ...