4 - 24
4. OPERATION
4.3.2 Manual pulse generator operation
(1) Setting
Set the input signal and parameters as follows according to the purpose of use. In this case, the point
table No. selection 1 to 5 (DI0 to DI4) are invalid.
Item Setting
method Description
Manual operation mode selection
Automatic/manual selection (MD0)
Open MD0-SG (OFF).
Manual pulse generator
multiplication
Parameter No.1
Set the multiplication ratio of servo
motor rotation to the pulses generated by
the manual pulse generator.
For more information, refer to (3) of this
section.
Servo motor rotation direction
Parameter No.1
Refer to (2) of this section.
(2) Servo motor rotation direction
Servo motor rotation direction
Parameter No. 1 setting
Manual pulse generator: forward rotation
Manual pulse generator: reverse rotation
0
CCW rotation
CW rotation
1
CW rotation
CCW rotation
Forward rotation
CCW
CW
(3) Manual pulse generator multiplication
(a) Using the parameter for setting
Use parameter No.1 to set the multiplication ratio of the servo motor rotation to the manual pulse
generator rotation.
Parameter No. 1 setting
Multiplication ratio of servo motor rotation to manual
pulse generator rotation
Moving distance
0
1
time
1[ m]
1
10
times
10[ m]
2
100
times
100[ m]
Содержание MR-J2S-10CP
Страница 11: ...A 10 MEMO ...
Страница 19: ...8 MEMO ...
Страница 45: ...1 26 1 FUNCTIONS AND CONFIGURATION MEMO ...
Страница 181: ...6 20 6 MR Configurator SERVO CONFIGURATION SOFTWARE MEMO ...
Страница 207: ...7 26 7 DISPLAY AND OPERATION MEMO ...
Страница 219: ...8 12 8 GENERAL GAIN ADJUSTMENT MEMO ...
Страница 229: ...9 10 9 SPECIAL ADJUSTMENT FUNCTIONS MEMO ...
Страница 231: ...10 2 10 INSPECTION MEMO ...
Страница 249: ...12 8 12 OUTLINE DIMENSION DRAWINGS MEMO ...
Страница 257: ...13 8 13 CHARACTERISTICS MEMO ...