7 - 17
7. DISPLAY AND OPERATION
(2) Signed 5-digit parameter
The following example gives the operation procedure to change the home position return position data
(parameter No. 42) to "-12345".
Setting of lower 4 digits
The screen flickers.
Enter the setting.
Setting of upper 1 digits
Press SET once.
Press MODE once.
Press SET once.
Press UP or DOWN to
change the setting.
Press SET once.
Press MODE once.
Note. The example assumes that the status display screen that appears at power-on has been
set to the servo motor speed in parameter No. 18.
Press MODE three times. Press UP or DOWN to choose parameter No. 42.
(Note)
When changing the parameter No. 42 setting, change its set value, then switch power off once and
switch it on again to make the new value valid.