6 - 14
6. MR Configurator (SERVO CONFIGURATION SOFTWARE)
6.7.2 Positioning operation
POINT
The servo motor will not operate if the forced stop (EMG), forward
rotation stroke end (LSP) and reverse rotation stroke end (LSN) are off.
Make automatic ON setting to turn on these devices or make device
setting to assign them as external input signals and turn ON across these
signals and SG. (Refer to section 6.6.)
When an alarm occurs, the positioning operation is automatically
canceled.
Click the “
Forward
” or “
Reverse
” button to start and rotate the servo motor by the preset moving distance
and then stop.
Click “
Test
” on the menu bar and click “
Positioning
” on the menu.
When the above choices are made, the following window appears.
d)
e)
f)
g)
a)
b)
c)