![Mitsubishi Electric FX3G SERIES Скачать руководство пользователя страница 918](http://html.mh-extra.com/html/mitsubishi-electric/fx3g-series/fx3g-series_programming-manual_238902918.webp)
916
FX
3G
/FX
3U
/FX
3UC
Series Programmable Controllers
Programming Manual - Basic & Applied Instruction Edition
B Instruction Execution Time
B-4 Applied Instruction Execution Time
Data operation
40
ZRST(D)
11.1 + 0.19n
⎯
0.325
⎯
n: Number of reset points
ZRST(T)
17.1 + 0.23n
⎯
0.325
⎯
n: Number of reset points
ZRST(M)
20.7 + 0.02n
⎯
0.325
⎯
n: Number of reset points
41
DECO
13.5
⎯
0.455
⎯
42
ENCO
18.0
⎯
0.455
⎯
43
SUM
12.7
16.9
0.325
0.585
44
BON
14.4
15.1
0.455
0.845
45
MEAN
11.8 + 0.41n
17.8 + 2.13n
0.455
0.845
46
ANS
20.4
⎯
19.7
⎯
47
ANR
7.0
⎯
0.065
⎯
48
SQR
9.7
12.1
0.325
0.585
49
FLT
9.8
9.5
0.325
0.585
High-speed processing
50
REF
4.5 + 1.39n
⎯
0.325
⎯
51
REFF
14.4 + 0.24n
⎯
0.195
⎯
52
MTR
5.9
⎯
5.5
⎯
53
HSCS
⎯
20.0
⎯
0.845
54
HSCR
⎯
20.0
⎯
0.845
55
HSZ
⎯
22.0
⎯
1.105
56
SPD
16.0
16.0
12.6
12.6
57
PLSY
20.0
13.6
6.9
6.9
58
PWM
10.6
⎯
6.2
⎯
59
PLSR
11.2
11.2
7.0
7.0
Handy instructions
60
IST
28.5
⎯
0.455
⎯
61
SER
16.4 + 1.4n
18.5 + 2.13n
0.585
1.105
62
ABSD
19 + 0.85n
20.0 + 1.23n
0.585
1.105
63
INCD
23.7
⎯
6.5
⎯
64
TTMR
10.4
⎯
9.2
⎯
65
STMR
19.0
⎯
21.0
⎯
66
ALT
11.6
⎯
0.2
⎯
67
RAMP
15.0
⎯
7.5
⎯
68
ROTC
25.8
⎯
24.8
⎯
69
SORT
18.4
⎯
6.6
⎯
External FX I/O device
70
TKY
21.5
21.8
5.2
5.2
71
HKY
32.0
32.3
5.7
5.7
72
DSW
26.8
⎯
22.1
⎯
73
SEGD
10.8
⎯
0.325
⎯
74
SEGL
22.3
⎯
7.5
⎯
75
ARWS
28.8
⎯
5.2
⎯
76
ASC
19.8
⎯
0.715
⎯
77
PR
24.0
⎯
13.6
⎯
FNC
No.
Instruction
Execution time in ON status (
μ
s)
Execution time in OFF status (
μ
s)
Remarks
16-bit instruction
32-bit instruction
16-bit instruction
32-bit instruction