9 Move and Compare – FNC 10 to FNC 19
9.8 FNC 17 – XCH / Exchange
1
Introdu
ction
2
Ov
ervi
ew
3
Instruction
Li
st
4
D
evices
in Det
ail
5
Specifi
ed the
De
vice
&
C
onst
ant
6
Bef
ore
Pr
og
ra
mmi
ng
7
Bas
ic
Instruction
8
FN
C00-FN
C0
9
Program Fl
ow
9
FNC
10-FN
C19
Mov
e & Com
pare
10
FNC
20-FNC
29
Arith. & Lo
gi
c
Operati
on
9.8
FNC 17 – XCH / Exchange
Outline
This instruction exchanges data between two devices.
1. Instruction format
2. Set data
3. Applicable devices
Explanation of function and operation
1. 16-bit operation (XCH and XCHP)
Data is exchanged between
and
.
2. 32-bit operation (DXCH and DXCHP)
Data is exchanged between [
+1,
] and [
+1,
].
Operand Type
Description
Data Type
Device number storing data to be exchanged.
16- or 32-bit binary
Device number storing data to be exchanged.
16- or 32-bit binary
Oper-
and
Type
Bit Devices
Word Devices
Others
System User
Digit Specification
System User
Special
Unit
Index
Con-
stant
Real
Number
Charac-
ter String
Pointer
X Y M T C S D
.b KnX KnY KnM KnS T C D R U
\G
V Z Modify K H
E
"
"
P
3
3
3
3 3 3 3
3
3 3
3
3
3
3
3 3 3 3
3
3 3
3
DXCH
DXCHP
Mnemonic
Operation Condition
16-bit Instruction
5 steps
XCH
XCHP
Mnemonic
Operation Condition
Continuous
Operation
Pulse (Single)
Operation
32-bit Instruction
9 steps
Continuous
Operation
Pulse (Single)
Operation
P
FNC 17
XCH
D
D
1
D
2
D
1
D
2
D
1
D
2
FNC 17
XCHP
D
1
D
2
Command
input
D
1
D
2
Before
execution
After
execution
K10
=
K36
=
K36
K10
=
=
Exchange
D
1
D
2
D
1
D
2
D
1
D
1
D
2
D
2
FNC 17
DXCHP
+1,
+1,
D
1
D
2
D
1
D
2
D
1
D
2
Command
input
K10000
=
K1433600
=
K1433600
K10000
=
=
+1,
+1,
+1,
+1,
Before execution
After execution
Exchange
D
1
D
2
D
1
D
2
D
1
D
2
D
1
D
2
Содержание FX3G SERIES
Страница 1: ...FX3G FX3U FX3UC SERIES PROGRAMMABLE CONTROLLERS PROGRAMMING MANUAL Basic Applied Instructions Edition ...
Страница 2: ......
Страница 947: ......