![Mitsubishi Electric FX3G SERIES Скачать руководство пользователя страница 849](http://html.mh-extra.com/html/mitsubishi-electric/fx3g-series/fx3g-series_programming-manual_238902849.webp)
847
FX
3G
/FX
3U
/FX
3UC
Series Programmable Controllers
Programming Manual - Basic & Applied Instruction Edition
37 Operation of Special Devices (M8000 -, D8000 -)
37.1 Special Device List (M8000 -, D8000 -)
31
FNC276
-F
NC2
79
Da
ta
Trans
fer 3
32
FNC28
0-F
NC
289
H
igh-Speed
Process
ing 2
33
FNC2
90-
FNC299
Ex
tensi
on Fi
le
Register
34
FN
C300-
FNC30
5
FX
3U
-C
F-
AD
P
35
SFC
•STL
Programming
36
Interrupt
Function
37
Sp
ec
ia
l D
evi
ce
38
E
rror Code
A
Ve
rsi
on U
p
Inform
ati
on
B
Ex
ecuti
on
T
imes
Inverter Communication Function (Refer to Data Communication Edition for details.)
D 8150
*1
Response wait time of inverter communication [ch1]
3
*4
3
3
–
–
–
–
–
–
[D]8151
Step number of instruction during inverter communication
[ch1]
Default: -1
3
*4
3
3
M8151
–
–
–
–
–
[D]8152
*2
Error code for inverter communication [ch1]
3
*4
3
3
M8152
–
–
–
–
–
[D]8153
*2
Inverter communication error step number latched [ch1]
Default: -1
3
*4
3
3
M8153
–
–
–
–
–
[D]8154
*2
Parameter number when error occurs during IVBWR
(FNC274) instruction [ch1]
Default: -1
–
3
3
M8154
–
–
–
–
–
Response waiting time of EXTR (FNC180) instruction
–
–
–
–
–
–
3
*3
–
3
*3
D 8155
*1
Response wait time of inverter communication [ch2]
3
*4
3
3
–
–
–
–
–
–
[D]8155
Step number during communication of EXTR
(FNC180) instruction
–
–
–
M8155
–
–
3
*3
–
3
*3
[D]8156
Step number of instruction during inverter communication
[ch2]
Default: -1
3
*4
3
3
M8156
–
–
–
–
–
Error code for EXTR (FNC180) instruction
–
–
–
M8156
–
–
3
*3
–
3
*3
[D]8157
*2
Error code for inverter communication [ch2]
3
*4
3
3
M8157
–
–
–
–
–
[D]8157
Error step (latched) for EXTR (FNC180) instruction
Default: -1
–
–
–
M8157
–
–
3
*3
–
3
*3
[D]8158
*2
Inverter communication error step number latched [ch2]
Default: -1
3
*4
3
3
M8158
–
–
–
–
–
[D]8159
*2
Parameter number when error occurs during IVBWR
(FNC274) instruction [ch2]
Default: -1
–
3
3
M8159
–
–
–
–
–
*1.
Cleared when PLC power supply is turned from OFF to ON.
*2.
Cleared when PLC switches from STOP to RUN.
*3.
Available in Ver. 3.00 or later.
*4.
Available in Ver. 1.10 or later.
Display Module Function [FX
1S
and FX
1N
]
D 8158
FX
1N
-5DM: Control device (D)
Default: -1
–
–
–
–
3
3
–
–
–
D 8159
FX
1N
-5DM: Control device (M)
Default: -1
–
–
–
–
3
3
–
–
–
Number and name
Content of register
Applicable model
FX
3G
FX
3U
FX
3UC
Correspond-
ing special
device
FX
1S
FX
1N
FX
2N
FX
1NC
FX
2NC
Содержание FX3G SERIES