597
FX
3G
/FX
3U
/FX
3UC
Series Programmable Controllers
Programming Manual - Basic & Applied Instruction Edition
24 Others – FNC181 to FNC189
24.5 FNC189 – HCMOV / High-Speed Counter Move
21
FNC160
-F
NC1
69
R
eal
T
ime C
lock
C
ontrol
22
FNC17
0-F
NC
179
E
xternal D
evice
23
FNC
180
Alternate
Instructions
24
FN
C181-
FNC18
9
O
thers
25
FNC190
-F
NC1
99
Bl
oc
k D
ata
Op
er
atio
n
26
FNC20
0-F
NC209
C
har
ac
te
r S
trin
g
Con
tro
l
27
FNC2
10-
FNC21
9
Dat
a
Operati
on 3
28
FNC220
-F
NC2
49
Da
ta
C
omp
ari
son
29
FNC25
0-F
N
C
269
D
ata T
abl
e
Operation
30
FNC2
70-
FNC275
Ex
-Dev
ice
Inverter C
om
m
s
24.5
FNC189 – HCMOV / High-Speed Counter Move
Outline
This instruction updates the current value of a specified high-speed counter or ring counter.
The function of this instruction varies depending on the PLC version.
1. Instruction format
2. Set data
3. Applicable devices
S
: Only high-speed counters (C235 to C255) and ring counters (D8099 and D8398)
*1
can be specified.
Explanation of function and operation
1. 32-bit operation (DHCMOV)
• The current value of a high-speed counter or ring counter specified in
is transferred to [
+1,
].
• After transfer, the current value of the high-speed counter or ring counter is processed as shown in the table below
depending on the set value of "n":
*1.
Ring counters (D8099 and D8398) cannot be specified in FX
3UC
PLCs before Ver. 2.20.
Operand Type
Description
Data Type
Device number of high-speed counter or ring counter*
1
handled as transfer source
32-bit binary
Device number handled as transfer destination
n
Specification to clear the current value of high-speed counter or ring counter*1 (transfer
source) after transfer [clear (K1), no clear (K0)]
16-bit binary
Oper-
and
Type
Bit Devices
Word Devices
Others
System User
Digit Specification
System User
Special
Unit
Index
Con-
stant
Real
Number
Charac-
ter String
Pointer
X Y M T C S D
.b KnX KnY KnM KnS T C D R U
\G
V
Z Modify K H
E
"
"
P
S S
3 3
n
3 3
Device
[
+1,
] after instruction is executed
High-speed counter
C235 to C255
Current value of high-speed counter
→
[
+1,
]
Ring counter
*1
D8099
D8099
→
"0" is stored in
+1.
D8398
Current value of [D8399, D8398]
→
[
+1,
]
"n" set value
Operation
K0 (H0)
Does not clear the current value (no processing).
K1 (H1)
Clears the current value to "0".
D
FNC 189
HCMOV
Mnemonic
Operation Condition
16-bit Instruction
13 steps DHCMOV
Mnemonic
Operation Condition
Continuous
Operation
32-bit Instruction
⎯
⎯
⎯
S
D
S
D
FNC189
DHCMOV
n
S
D
Command
input
S
D
D
S
D
D
S
D
D
D
D
D
D
Содержание FX3G SERIES
Страница 1: ...FX3G FX3U FX3UC SERIES PROGRAMMABLE CONTROLLERS PROGRAMMING MANUAL Basic Applied Instructions Edition ...
Страница 2: ......