![Mitsubishi Electric FX3G SERIES Скачать руководство пользователя страница 897](http://html.mh-extra.com/html/mitsubishi-electric/fx3g-series/fx3g-series_programming-manual_238902897.webp)
895
FX
3G
/FX
3U
/FX
3UC
Series Programmable Controllers
Programming Manual - Basic & Applied Instruction Edition
A Programming Tool Applicability and Version Upgrade History
A-1 Programming Tool Applicability
31
FNC276
-F
NC2
79
Da
ta
Trans
fer 3
32
FNC28
0-F
NC
289
H
igh-Speed
Process
ing 2
33
FNC2
90-
FNC299
Ex
tensi
on Fi
le
Register
34
FN
C300-
FNC30
5
FX
3U
-C
F-
AD
P
35
SFC
•STL
Programming
36
Interrupt
Function
37
Sp
ec
ia
l D
evi
ce
38
E
rror Code
A
Ve
rsi
on U
p
Inform
ati
on
B
Ex
ecuti
on
T
imes
Appendix A-1-2
Cautions on writing during RUN
"In the FX
3G
, FX
3U
and FX
3UC
PLCs, writing is enabled during RUN (program changes during RUN mode) using the
following programming tools."
→
For the operating procedure of and cautions on writing during RUN,
refer to the respective programming tool manual.
Programming tools which support writing during RUN
• Japanese version
*1.
Write during RUN is not possible with a SFC program.
*2.
Write during RUN is not possible with a list program or a SFC program.
Programming tool
PLC
Version
Remarks
GX Works2
*1
(SW
DNC-GXW2-J)
FX
3G
Ver. 1.07H or later
Writing in the instruction and device ranges during RUN is supported in FX
3G
PLCs Ver. 1.10.
FX
3U
/FX
3UC
Ver. 1.07H or later
Writing in the instruction and device ranges during RUN is supported in FX
3U
and
FX
3UC
PLCs earlier than Ver. 2.70.
Ver. 1.45X or later
Writing in the instruction and device ranges during RUN is supported in FX
3U
and
FX
3UC
PLCs Ver. 2.70.
GX Developer
*2
(SW
D5C-GPPW-J)
FX
3G
Ver. 2.00A or later
Writing in the instruction and device ranges during RUN is supported in FX
2N
PLCs Ver. 1.00.
Ver. 5.00A or later
Writing in the instruction and device ranges during RUN is supported in FX
1N
PLCs Ver. 1.00.
Ver. 8.72A or later
Writing in the instruction and device ranges during RUN is supported in FX
3G
PLCs earlier than Ver. 1.10.
Ver. 8.76E or later
Writing in the instruction and device ranges during RUN is supported in FX
3G
PLCs Ver. 1.10.
FX
3U
/FX
3UC
Ver. 7.00A or later
Writing in the instruction and device ranges during RUN is supported in FX
2N
PLCs Ver. 3.00.
Ver. 8.13P or later
Writing in the instruction and device ranges during RUN is supported in FX
3UC
PLCs earlier than Ver. 1.30.
Ver. 8.18U or later
Writing in the instruction and device ranges during RUN is supported in FX
3UC
PLCs earlier than Ver. 2.20.
Ver. 8.23Z or later
Writing in the instruction and device ranges during RUN is supported in FX
3U
and
FX
3UC
PLCs earlier than Ver. 2.30.
Ver. 8.29F or later
Writing in the instruction and device ranges during RUN is supported in FX
3U
and
FX
3UC
PLCs earlier than Ver. 2.61.
Ver. 8.82L or later
Writing in the instruction and device ranges during RUN is supported in FX
3U
and
FX
3UC
PLCs Ver. 2.61.
FX-PCS/WIN
*2
FX
3G
Ver. 4.00 or later
Writing in the instruction and device ranges during RUN is supported in FX
1N
PLCs Ver. 1.00.
FX
3U
/FX
3UC
Ver. 1.00 or later
Writing in the instruction and device ranges during RUN is supported in FX
2
PLCs Ver. 3.30.
Ver. 2.00 or later
Writing in the instruction and device ranges during RUN is supported in FX
2N
PLCs Ver. 1.00.
Ver. 4.20 or later
Writing in the instruction and device ranges during RUN is supported in FX
2N
PLCs Ver. 3.00.