![Mitsubishi Electric FX3G SERIES Скачать руководство пользователя страница 258](http://html.mh-extra.com/html/mitsubishi-electric/fx3g-series/fx3g-series_programming-manual_238902258.webp)
256
FX
3G
/FX
3U
/FX
3UC
Series Programmable Controllers
Programming Manual - Basic & Applied Instruction Edition
9 Move and Compare – FNC 10 to FNC 19
9.6 FNC 15 – BMOV / Block Move
Extension function (bi-directional transfer function)
By controlling the direction inverse flag M8024
*1
for BMOV (FNC 15) instruction, data can be transferred in two
directions in one program.
*1.
M8024 is cleared when the PLC mode is changed from RUN to STOP.
Caution
When specifying digits of bit devices, specify the same number of digits for
and
.
BMOV direction inverse
flag
Transfer
direction
,
M8024
*1
: OFF
→
D5
→
D10
D6
→
D11
D7
→
D12
M8024
*1
: ON
←
D5
←
D10
D6
←
D11
D7
←
D12
X000
FNC 15
BMOVP
D5
D10
K3
X001
M8024
BMOV
direction
inverse flag
M8001
M8024
BMOV
direction
inverse flag:
OFF
Normally OFF
during operation
n
*1
*1
S
D
S
D
S
D
S
D
S
D
n
n = 2
Y000
Y001
Y002
M 0
M 1
M 2
M 3
Y003
Y004
Y005
Y006
M 4
M 5
M 6
M 7
Y007
Specify the same number
of digits.
(Example: K1)
M8000
FNC 15
BMOV
K1M0
K1Y000
K 2
S
D