Parameters
(A) Application parameters
FR-A800
5 - 513
5.14.6
Load torque high speed frequency control
Load torque high-speed frequency control is a function that automatically sets the maximum
operable frequency according to the load.
The load size during power driving is estimated by detecting average currents at set timings after a
start. When the load is light, the frequency is increased from the originally-set frequency. (In regen-
erative driving, the frequency is not increased.)
This function is designed to increase speed automatically under light load, for example to minimize
the incoming/outgoing time in a multi-story parking lot.
I002678E
Fig. 5-240:
Increased speed under light load
Pr.
Name
Initial value
Setting
range
Description
FM
CA
4
D301
Multi-speed setting (high
speed)
60 Hz 50 Hz 0 to 590 Hz Set the higher-speed frequency.
5
D302
Multi-speed setting
(middle speed)
30 Hz
0 to 590 Hz Set the lower-speed frequency.
270
A200
Stop-on contact/load
torque high-speed
frequency control selection
0
0
Normal operation
1
Stop-on-contact control (Refer to page 5-509.)
2
Load torque high-speed frequency control
3
Stop-on-contact (refer to page 5-509) + load torque
high- speed frequency control
11
Stop-on-contact control
E.OLT invalid
under stop-on-
contact control
13
Stop-on-c load torque high-
speed frequency control
(Refer to page 5-509.)
271
A201
High-speed setting
maximum current
50%
0 to 400%
Set the upper and lower limits of the current at high
and middle speeds.
272
A202
Middle-speed setting
minimum current
100%
0 to 400%
273
A203
Current averaging range
9999
0 to 590 Hz
Set the average current during acceleration from
(Pr. 273 × 1/2) Hz to (Pr. 273) Hz.
9999
Set the average current during acceleration from
(Pr. 5 × 1/2) Hz to (Pr. 5) Hz.
274
A204
Current averaging filter
time constant
16
1 to 4000
Set the time constant of the primary delay filter relative
to the output current.
(The time constant [ms] is 0.5 × Pr. 274, and the initial
value is 8 ms.)
A larger setting results in a stable operation with
poorer response.
<Without high-speed
frequency control>
<With high-speed
frequency control>
Light
Faster
The lift with a light load or without
a load is moved faster than the lift
with a load.
(The output frequency is increased
only during power driving.)
Whether there is a load or
not, the lift is moved
vertically at the same speed.
Содержание FR-A820-00046 (0.4K)
Страница 2: ......
Страница 4: ......
Страница 144: ...System configuration for Ethernet communication FR A800 E Installation and wiring 2 114 ...
Страница 202: ...Basic operation procedure JOG operation Basic operation 4 32 ...
Страница 1090: ...Check first when you have a trouble Protective functions 6 50 ...
Страница 1110: ...Measurement of main circuit voltages currents and powers Precautions for maintenance and inspection 7 20 ...
Страница 1188: ...EC Declarations of Conformity Appendix A 48 A 7 EC Declarations of Conformity A 7 1 FR A820 FR A840 FR A842 series ...
Страница 1189: ...Appendix EC Declarations of Conformity FR A800 A 49 ...
Страница 1190: ...EC Declarations of Conformity Appendix A 50 ...
Страница 1191: ...Appendix EC Declarations of Conformity FR A800 A 51 ...
Страница 1192: ...EC Declarations of Conformity Appendix A 52 ...
Страница 1193: ...Appendix EC Declarations of Conformity FR A800 A 53 ...
Страница 1194: ...EC Declarations of Conformity Appendix A 54 ...
Страница 1195: ...Appendix EC Declarations of Conformity FR A800 A 55 ...
Страница 1196: ...EC Declarations of Conformity Appendix A 56 ...
Страница 1197: ...Appendix EC Declarations of Conformity FR A800 A 57 ...
Страница 1198: ...EC Declarations of Conformity Appendix A 58 ...
Страница 1199: ...Appendix EC Declarations of Conformity FR A800 A 59 ...
Страница 1200: ...EC Declarations of Conformity Appendix A 60 ...
Страница 1201: ...Appendix EC Declarations of Conformity FR A800 A 61 ...
Страница 1202: ...EC Declarations of Conformity Appendix A 62 ...
Страница 1203: ...Appendix EC Declarations of Conformity FR A800 A 63 ...
Страница 1204: ...EC Declarations of Conformity Appendix A 64 ...
Страница 1205: ...Appendix EC Declarations of Conformity FR A800 A 65 ...
Страница 1206: ...EC Declarations of Conformity Appendix A 66 ...
Страница 1207: ...Appendix EC Declarations of Conformity FR A800 A 67 ...
Страница 1208: ...EC Declarations of Conformity Appendix A 68 ...
Страница 1209: ...Appendix EC Declarations of Conformity FR A800 A 69 ...
Страница 1210: ...EC Declarations of Conformity Appendix A 70 ...
Страница 1211: ...Appendix EC Declarations of Conformity FR A800 A 71 ...
Страница 1212: ...EC Declarations of Conformity Appendix A 72 A 7 2 FR A846 series ...
Страница 1213: ...Appendix EC Declarations of Conformity FR A800 A 73 ...
Страница 1214: ...EC Declarations of Conformity Appendix A 74 ...
Страница 1215: ...Appendix EC Declarations of Conformity FR A800 A 75 ...
Страница 1216: ...EC Declarations of Conformity Appendix A 76 A 7 3 Frequency inverters with option unit FR A8NP ...
Страница 1217: ......