Parameters
(M) Monitor display and monitor output signal
FR-A800
5 - 347
Torque current
command
0.1%
33
H21
40233
Displays the commanded
current for the torque.
Motor output
0.01 kW/
0.1 kW
34
H22
40234
Multiplies the output torque at
that time with the motor speed,
and displays the machine output
for the motor shaft end.
Feedback pulse
⎯
35
H23
40235
Display the number of pulses fed
back from the encoder during
one sampling (also displays
during stop). ((Displays the
voltage monitor when a vector
control compatible option is not
connected.)
The sampling time varies with
the Pr. 369 "Number of encoder
pulses setting".
1050 or less: 1 s
1051 to 2100: 0.5 s
2101 to 4096: 0.25 s
Torque monitor
(power driving/
regenerative
driving polarity
switching)
0.1%
36
H24
40236
Displays the same value as that
of the motor torque. Displays
plus value for power driving and
negative value for regenerative
driving.
Trace status
1
38
H26
40238
Displays the trace status. (Refer
to page page 5-610)
PLC function
user monitor 1
Accord-
ing to the
SD1215
setting
40
H28
40240
Displays the arbitrary monitoring
item using the PLC function.
Displays the following special
register values.
SD1216: Displays in No. 40
SD1217: Displays in No. 41
SD1218: Displays in No. 42
(Refer to the PLC Function
Programming Manual.)
PLC function
user monitor 2
41
H29
40241
PLC function
user monitor 3
42
H2A
40242
Station number
(RS-485
terminals)
1
43
H2B
40243
Displays which station number (0
to 31) can currently be used for
communication from the RS-485
terminal block.
Station number
(PU)
1
44
H2C
40244
Displays which station number (0
to 31) can currently be used for
communication from the PU
connector.
Station number
(CC-Link)
1
45
H2D
40245
Displays which station number (0
to 31) can currently be used for
CC-Link communication.
Displays "0" when the FR-A8NC is
not connected.
Motor
temperature
1 °C
46
H2E
40246
Display the temperature of the
vector control dedicated motor
with thermistor
(SF-V5RU
첸첸첸첸첸
T/A)
(for FR-A8AZ)
Energy saving
effect
Changea-
ble by pa-
rameter
setting.
50
H32
40250
Displays the energy saving effect
monitor.
Conversion to power saving,
average power saving, price
display, and percentage display
can be done using parameters.
(Refer to page 5-197.)
Cumulative
energy saving
51
H33
40251
PID set point
0.1%
52
H34
40252
Displays the set point, measured
value, and deviation under PID
control.
(Refer to page page 5-556)
PID measured
value
0.1%
53
H35
40253
PID deviation
0.1%
54
H36
40254
Types of
monitor
Unit
Pr. 52,
Pr. 774 to Pr. 776,
Pr. 992
RS-485
communica-
tion dedicat-
ed monitor
(hexadeci-
mal)
Modbus®
RTU real
time
monitor
Minus (-)
display
Description
Tab. 5-130:
Monitor description list (3)
Содержание FR-A820-00046 (0.4K)
Страница 2: ......
Страница 4: ......
Страница 144: ...System configuration for Ethernet communication FR A800 E Installation and wiring 2 114 ...
Страница 202: ...Basic operation procedure JOG operation Basic operation 4 32 ...
Страница 1090: ...Check first when you have a trouble Protective functions 6 50 ...
Страница 1110: ...Measurement of main circuit voltages currents and powers Precautions for maintenance and inspection 7 20 ...
Страница 1188: ...EC Declarations of Conformity Appendix A 48 A 7 EC Declarations of Conformity A 7 1 FR A820 FR A840 FR A842 series ...
Страница 1189: ...Appendix EC Declarations of Conformity FR A800 A 49 ...
Страница 1190: ...EC Declarations of Conformity Appendix A 50 ...
Страница 1191: ...Appendix EC Declarations of Conformity FR A800 A 51 ...
Страница 1192: ...EC Declarations of Conformity Appendix A 52 ...
Страница 1193: ...Appendix EC Declarations of Conformity FR A800 A 53 ...
Страница 1194: ...EC Declarations of Conformity Appendix A 54 ...
Страница 1195: ...Appendix EC Declarations of Conformity FR A800 A 55 ...
Страница 1196: ...EC Declarations of Conformity Appendix A 56 ...
Страница 1197: ...Appendix EC Declarations of Conformity FR A800 A 57 ...
Страница 1198: ...EC Declarations of Conformity Appendix A 58 ...
Страница 1199: ...Appendix EC Declarations of Conformity FR A800 A 59 ...
Страница 1200: ...EC Declarations of Conformity Appendix A 60 ...
Страница 1201: ...Appendix EC Declarations of Conformity FR A800 A 61 ...
Страница 1202: ...EC Declarations of Conformity Appendix A 62 ...
Страница 1203: ...Appendix EC Declarations of Conformity FR A800 A 63 ...
Страница 1204: ...EC Declarations of Conformity Appendix A 64 ...
Страница 1205: ...Appendix EC Declarations of Conformity FR A800 A 65 ...
Страница 1206: ...EC Declarations of Conformity Appendix A 66 ...
Страница 1207: ...Appendix EC Declarations of Conformity FR A800 A 67 ...
Страница 1208: ...EC Declarations of Conformity Appendix A 68 ...
Страница 1209: ...Appendix EC Declarations of Conformity FR A800 A 69 ...
Страница 1210: ...EC Declarations of Conformity Appendix A 70 ...
Страница 1211: ...Appendix EC Declarations of Conformity FR A800 A 71 ...
Страница 1212: ...EC Declarations of Conformity Appendix A 72 A 7 2 FR A846 series ...
Страница 1213: ...Appendix EC Declarations of Conformity FR A800 A 73 ...
Страница 1214: ...EC Declarations of Conformity Appendix A 74 ...
Страница 1215: ...Appendix EC Declarations of Conformity FR A800 A 75 ...
Страница 1216: ...EC Declarations of Conformity Appendix A 76 A 7 3 Frequency inverters with option unit FR A8NP ...
Страница 1217: ......