Parameter List
Parameters
5 - 40
(D) Operation command and frequency command
Parameters that specify the inverter's command source,
and parameters that set the motor driving frequency and
torque.
(H) Protective function parameter
Parameters to protect the motor and the inverter.
Pr.
group
Pr.
Name
Refer to
page
D000
79
Operation mode selection
D001
340
Communication startup mode
selection
D010
338
Communication operation
command source
D011
339
Communication speed command
source
D012
550
NET mode operation command
source selection
D013
551
PU mode operation command
source selection
D020
78
Reverse rotation prevention
selection
D030
811
Set resolution switchover
D100
291
Pulse train I/O selection
D101
384
Input pulse division scaling factor
D110
385
Frequency for zero input pulse
D111
386
Frequency for maximum input pulse
D200
15
Jog frequency
D300
28
Multi-speed input compensation
selection
D301
4
Multi-speed setting (high speed)
D302
5
Multi-speed setting (middle speed)
D303
6
Multi-speed setting (low speed)
D304 to
D307
24 to 27
Multi-speed setting
(4 speed to 7 speed)
D308 to
D315
232 to
239
Multi-speed setting
(8 speed to 15 speed)
D400
804
Torque command source selection
D401
805
Torque command value (RAM)
D402
806
Torque command value (RAM,
EEPROM)
D403
1114
Torque command reverse selection
Tab. 5-8:
Operation command and frequency
command
Simple
Simple
Simple
Simple
Simple
Simple
Simple
Simple
Simple
Simple
Simple
Simple
Pr.
group
Pr.
Name
Refer to
page
H000
9
Electronic thermal O/L relay
H001
600
First free thermal reduction
frequency 1
H002
601
First free thermal reduction ratio 1
H003
602
First free thermal reduction
frequency 2
H004
603
First free thermal reduction ratio 2
H005
604
First free thermal reduction
frequency 3
H006
607
Motor permissible load level
H010
51
Second electronic thermal O/L relay
H011
692
Second free thermal reduction
frequency 1
H012
693
Second free thermal reduction ratio 1
H013
694
Second free thermal reduction
frequency 2
H014
695
Second free thermal reduction ratio 2
H015
696
Second free thermal reduction
frequency 3
H016
608
Second motor permissible load level
H020
561
PTC thermistor protection level
H021
1016
PTC thermistor protection detection
time
H022
876
Thermal protector input
H030
875
Fault definition
H100
244
Cooling fan operation selection
H101
249
Earth (ground) fault detection at start
H102
598
Undervoltage level
H103
997
Fault initiation
H200
251
Output phase loss protection
selection
H201
872
Input phase loss protection selection
H300
65
Retry selection
H301
67
Number of retries at fault occurrence
H302
68
Retry waiting time
H303
69
Retry count display erase
H400
1
Maximum frequency
H401
2
Minimum frequency
H402
18
High speed maximum frequency
H410
807
Speed limit selection
H411
808
Forward rotation speed limit/speed
limit
H412
809
Reverse rotation speed limit/reverse-
side speed limit
Tab. 5-9:
Protective function parameter (1)
Simple
Simple
Simple
Simple
Simple
Simple
Simple
Simple
Simple
Содержание FR-A820-00046 (0.4K)
Страница 2: ......
Страница 4: ......
Страница 144: ...System configuration for Ethernet communication FR A800 E Installation and wiring 2 114 ...
Страница 202: ...Basic operation procedure JOG operation Basic operation 4 32 ...
Страница 1090: ...Check first when you have a trouble Protective functions 6 50 ...
Страница 1110: ...Measurement of main circuit voltages currents and powers Precautions for maintenance and inspection 7 20 ...
Страница 1188: ...EC Declarations of Conformity Appendix A 48 A 7 EC Declarations of Conformity A 7 1 FR A820 FR A840 FR A842 series ...
Страница 1189: ...Appendix EC Declarations of Conformity FR A800 A 49 ...
Страница 1190: ...EC Declarations of Conformity Appendix A 50 ...
Страница 1191: ...Appendix EC Declarations of Conformity FR A800 A 51 ...
Страница 1192: ...EC Declarations of Conformity Appendix A 52 ...
Страница 1193: ...Appendix EC Declarations of Conformity FR A800 A 53 ...
Страница 1194: ...EC Declarations of Conformity Appendix A 54 ...
Страница 1195: ...Appendix EC Declarations of Conformity FR A800 A 55 ...
Страница 1196: ...EC Declarations of Conformity Appendix A 56 ...
Страница 1197: ...Appendix EC Declarations of Conformity FR A800 A 57 ...
Страница 1198: ...EC Declarations of Conformity Appendix A 58 ...
Страница 1199: ...Appendix EC Declarations of Conformity FR A800 A 59 ...
Страница 1200: ...EC Declarations of Conformity Appendix A 60 ...
Страница 1201: ...Appendix EC Declarations of Conformity FR A800 A 61 ...
Страница 1202: ...EC Declarations of Conformity Appendix A 62 ...
Страница 1203: ...Appendix EC Declarations of Conformity FR A800 A 63 ...
Страница 1204: ...EC Declarations of Conformity Appendix A 64 ...
Страница 1205: ...Appendix EC Declarations of Conformity FR A800 A 65 ...
Страница 1206: ...EC Declarations of Conformity Appendix A 66 ...
Страница 1207: ...Appendix EC Declarations of Conformity FR A800 A 67 ...
Страница 1208: ...EC Declarations of Conformity Appendix A 68 ...
Страница 1209: ...Appendix EC Declarations of Conformity FR A800 A 69 ...
Страница 1210: ...EC Declarations of Conformity Appendix A 70 ...
Страница 1211: ...Appendix EC Declarations of Conformity FR A800 A 71 ...
Страница 1212: ...EC Declarations of Conformity Appendix A 72 A 7 2 FR A846 series ...
Страница 1213: ...Appendix EC Declarations of Conformity FR A800 A 73 ...
Страница 1214: ...EC Declarations of Conformity Appendix A 74 ...
Страница 1215: ...Appendix EC Declarations of Conformity FR A800 A 75 ...
Страница 1216: ...EC Declarations of Conformity Appendix A 76 A 7 3 Frequency inverters with option unit FR A8NP ...
Страница 1217: ......