62
Parameter list
PID
op
er
at
io
n
553
PID deviation limit
0 to 100.0%, 9999
0.1%
9999
219
554
PID signal operation selection
0 to 3, 10 to 13
1
0
219
Cu
rr
en
t a
ve
ra
ge
mo
ni
to
r
555
Current average time
0.1 to 1.0s
0.1s
1s
255
556
Data output mask time
0.0 to 20.0s
0.1s
0s
255
557
Current average value monitor signal
output reference current
0 to 500A/0 to 3600A
0.01/0.1A
Rated
inverter
current
255
563
Energization time carrying-over times
(0 to 65535)
1
0
126
564
Operating time carrying-over times
(0 to 65535)
1
0
126
Mu
lti
pl
e
ra
tin
g
570
Multiple rating setting
0, 1
1
0
75
571
Holding time at a start
0.0 to 10.0s, 9999
0.1s
9999
92
573
4mA input check selection
1, 9999
1
9999
167
PI
D
c
ont
ro
l
575
Output interruption detection time
0 to 3600s, 9999
0.1s
1s
219
576
Output interruption detection level
0 to 400Hz
0.01Hz
0Hz
219
577
Output interruption cancel level
900 to 1100%
0.1%
1000%
219
Pu
m
p
fu
nc
tio
n
578
Auxiliary motor operation selection
0 to 3
1
0
236
579
Motor connection function selection
0 to 3
1
0
236
580
MC switching interlock time
0 to 100s
0.1s
1s
236
581
Start waiting time
0 to 100s
0.1s
1s
236
582
Auxiliary motor connection-time
deceleration time
0 to 3600/360s, 9999
0.1/0.01s
1s
236
583
Auxiliary motor disconnection-time
acceleration time
0 to 3600/360s, 9999
0.1/0.01s
1s
236
584
Auxiliary motor 1 starting frequency
0 to 400Hz
0.01Hz
50Hz
236
585
Auxiliary motor 2 starting frequency
0 to 400Hz
0.01Hz
50Hz
236
586
Auxiliary motor 3 starting frequency
0 to 400Hz
0.01Hz
50Hz
236
587
Auxiliary motor 1 stopping frequency
0 to 400Hz
0.01Hz
0Hz
236
588
Auxiliary motor 2 stopping frequency
0 to 400Hz
0.01Hz
0Hz
236
589
Auxiliary motor 3 stopping frequency
0 to 400Hz
0.01Hz
0Hz
236
590
Auxiliary motor start detection time
0 to 3600s
0.1s
5s
236
591
Auxiliary motor stop detection time
0 to 3600s
0.1s
5s
236
Tr
av
e
rs
e
fu
nc
tio
n
592
Traverse function selection
0, 1, 2
1
0
246
593
Maximum amplitude amount
0 to 25%
0.1%
10%
246
594
Amplitude compensation amount
during deceleration
0 to 50%
0.1%
10%
246
595
Amplitude compensation amount
during acceleration
0 to 50%
0.1%
10%
246
596
Amplitude acceleration time
0.1 to 3600s
0.1s
5s
246
597
Amplitude deceleration time
0.1 to 3600s
0.1s
5s
246
611
Acceleration time at a restart
0 to 3600s, 9999
0.1s
5/15s
136
Sp
e
ed
sm
oo
thi
ng
co
nt
ro
l
653
Speed smoothing control
0 to 200%
0.1%
0
154
654
Speed smoothing cutoff frequency
0 to 120Hz
0.01Hz
20Hz
154
799
Pulse increment setting for output
power
0.1kWh, 1kWh, 10kWh,
100kWh, 1000kWh
0.1
1kWh
124
867
AM output filter
0 to 5s
0.01s
0.01s
131
869
Current output filter
0 to 5s
0.01s
0.02s
131
Function Parameters
Name
Setting Range
Minimum
Setting
Increments
Initial
Value
Refer
to
Page