15 - 17
MELSEC-Q
15 TROUBLESHOOTING
Related buffer memory
address
Set range
(Setting with sequence program)
Remedy
Axis 1 Axis 2 Axis 3 Axis 4
Refer to Section 5.4
"List of block start data"
<Condition data No.>
1 to 10
Review the condition data No.
(Refer to Section 5.4 Da.14 )
Refer to Section 5.5
"List of condition data"
<Condition operators>
Axis designation:
10
H
, 20
H
, 30
H
, 40
H
, 50
H
,
60
H
, 70
H
, 80
H
, 90
H
, A0
H
,
B0
H
, C0
H
, D0
H
, E0
H
Normalize the condition operators.
(Refer to Section 5.5 Da.16 )
1540 1640 1740 1840 Axis 1 start data No.
Simultaneous
start axis start
data No.
0 to 600
Normalize the simultaneous start axis start data No.
(Refer to Section 10.5)
1541 1641 1741 1841 Axis 2 start data No.
1542 1642 1742 1842 Axis 3 start data No.
1543 1643 1743 1843 Axis 4 start data No.
1500 1600 1700 1800
<Positioning start No.>
1 to 600,
7000 to 7004,
9001 to 9004
Normalize the positioning start No., positioning start
data (in block start), and positioning data (in JUMP
instruction).
Refer to Section 5.3
"List of positioning data"
<JUMP destination>
1 to 600
<Command speed>
QD75P N/QD75D N:
1 to 4000000 [pulse/s]
1 to 2000000000
[
10
-2
mm/min or others]
QD75P /QD75D :
1 to 1000000 [pulse/s]
1 to 2000000000
[
10
-2
mm/min or others]
Normalize the positioning data.
Содержание D75D4
Страница 2: ......
Страница 22: ...A 20 MEMO ...
Страница 24: ...MEMO ...
Страница 41: ...1 17 MELSEC Q 1 PRODUCT OUTLINE MEMO ...
Страница 48: ...1 24 MELSEC Q 1 PRODUCT OUTLINE MEMO ...
Страница 58: ...2 10 MELSEC Q 2 SYSTEM CONFIGURATION MEMO ...
Страница 65: ...3 7 MELSEC Q 3 SPECIFICATIONS AND FUNCTIONS ...
Страница 139: ...5 35 MELSEC Q 5 DATA USED FOR POSITIONING CONTROL MEMO ...
Страница 238: ...5 134 MELSEC Q 5 DATA USED FOR POSITIONING CONTROL MEMO ...
Страница 251: ...6 13 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL ...
Страница 254: ...6 16 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL ...
Страница 255: ...6 17 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL ...
Страница 256: ...6 18 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL ...
Страница 259: ...6 21 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL ...
Страница 260: ...6 22 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL ...
Страница 292: ...7 8 MELSEC Q 7 MEMORY CONFIGURATION AND DATA PROCESS ...
Страница 294: ...7 10 MELSEC Q 7 MEMORY CONFIGURATION AND DATA PROCESS ...
Страница 298: ...MEMO ...
Страница 462: ...9 140 MELSEC Q 9 MAJOR POSITIONING CONTROL MEMO ...
Страница 490: ...10 28 MELSEC Q 10 HIGH LEVEL POSITIONING CONTROL MEMO ...
Страница 524: ...11 34 MELSEC Q 11 MANUAL CONTROL Creating the program ...
Страница 666: ...14 24 MELSEC Q 14 DEDICATED INSTRUCTIONS MEMO ...
Страница 675: ...15 9 MELSEC Q 15 TROUBLESHOOTING MEMO ...
Страница 716: ...15 50 MELSEC Q 15 TROUBLESHOOTING MEMO ...
Страница 724: ...Appendix 8 MELSEC Q APPENDICES Axis address mm inch degree pulse Axis address mm inch degree pulse ...
Страница 725: ...Appendix 9 MELSEC Q APPENDICES MEMO ...
Страница 731: ...Appendix 15 MELSEC Q APPENDICES Initial value Axis 1 Axis 2 Axis 3 Axis 4 Remarks 0 0 0 0 1 1 0 0 0 0 0 0 300 11 0 0 ...
Страница 875: ...Appendix 159 MELSEC Q APPENDICES Appendix 14 External dimension drawing 1 QD75P1N Unit mm 23 4 27 4 98 90 46 ...
Страница 876: ...Appendix 160 MELSEC Q APPENDICES 2 QD75P2N Unit mm 23 27 4 90 4 98 46 3 QD75P4N 23 27 4 90 4 98 46 Unit mm ...
Страница 877: ...Appendix 161 MELSEC Q APPENDICES 4 QD75D1N 12 90 23 27 4 Unit mm 98 4 46 5 QD75D2N 90 23 27 4 12 98 4 46 Unit mm ...
Страница 878: ...Appendix 162 MELSEC Q APPENDICES 6 QD75D4N 90 23 27 4 12 98 4 46 Unit mm ...
Страница 879: ...Appendix 163 MELSEC Q APPENDICES 7 QD75P1 QD75P2 QD75P4 27 4 23 98 90 4 46 unit mm ...
Страница 880: ...Appendix 164 MELSEC Q APPENDICES 8 QD75D1 QD75D2 QD75D4 27 4 23 90 12 98 4 46 unit mm ...
Страница 893: ...WARRANTY ...
Страница 895: ......