Appendix - 52
MELSEC-Q
APPENDICES
Appendix 5 Connection examples with stepping motors manufactured by
ORIENTALMOTOR Co., Ltd.
Appendix 5.1 Connection example of QD75P N and VEXTA UPD (Open collector)
4
PULSE F
PULSE COM
PULSE R
PULSE COM
PG024
PG0 COM
READY
RDY COM
PULSER A+
PULSER A-
PULSER B+
PULSER B-
12
A19
B19
A20
B20
DOG
FLS
RLS
STOP
CHG
COM
COM
3
1
2
4
5
15
16
17
18
8
10
11
24G
P24V
P5V
5G
VEXTA UPD
*3
5V
A
B
0V
CW+
CCW-
CW-
CCW+
H.OFF+
H.OFF-
TIMING
COM
O.H
5G
*1
QD75P N
6
7
Upper limit
Stop
External command
*2
*2
Near-point dog
Lower limit
+5V
Manual pulse
generator
MR-HDP01
Connect when required
Within 2m *5
REMARK
(1) 1: The logic for each I/O terminal can be changed with " Pr.22 Input signal logic selection" and " Pr.23
Output signal logic selection" in detailed parameters 1. (Negative logic is used for all terminals in the example
above.)
(2) 2: The QD75P N upper limit (FLS) and lower limit (RLS) are used in the OPR retry function.
(3) 3: Refer to the manual of the stepping motor drive for information on the stepping motor drive side wiring and
various signal wire shields not shown above.
(4) 4: Use the same logic (positive logic/negative logic) for the QD75P N and stepping motor. The QD75P N is
initially set to negative logic.
(5) 5: This indicates the distance between the QD75P N and VEXTA UPD.
Содержание D75D4
Страница 2: ......
Страница 22: ...A 20 MEMO ...
Страница 24: ...MEMO ...
Страница 41: ...1 17 MELSEC Q 1 PRODUCT OUTLINE MEMO ...
Страница 48: ...1 24 MELSEC Q 1 PRODUCT OUTLINE MEMO ...
Страница 58: ...2 10 MELSEC Q 2 SYSTEM CONFIGURATION MEMO ...
Страница 65: ...3 7 MELSEC Q 3 SPECIFICATIONS AND FUNCTIONS ...
Страница 139: ...5 35 MELSEC Q 5 DATA USED FOR POSITIONING CONTROL MEMO ...
Страница 238: ...5 134 MELSEC Q 5 DATA USED FOR POSITIONING CONTROL MEMO ...
Страница 251: ...6 13 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL ...
Страница 254: ...6 16 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL ...
Страница 255: ...6 17 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL ...
Страница 256: ...6 18 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL ...
Страница 259: ...6 21 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL ...
Страница 260: ...6 22 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL ...
Страница 292: ...7 8 MELSEC Q 7 MEMORY CONFIGURATION AND DATA PROCESS ...
Страница 294: ...7 10 MELSEC Q 7 MEMORY CONFIGURATION AND DATA PROCESS ...
Страница 298: ...MEMO ...
Страница 462: ...9 140 MELSEC Q 9 MAJOR POSITIONING CONTROL MEMO ...
Страница 490: ...10 28 MELSEC Q 10 HIGH LEVEL POSITIONING CONTROL MEMO ...
Страница 524: ...11 34 MELSEC Q 11 MANUAL CONTROL Creating the program ...
Страница 666: ...14 24 MELSEC Q 14 DEDICATED INSTRUCTIONS MEMO ...
Страница 675: ...15 9 MELSEC Q 15 TROUBLESHOOTING MEMO ...
Страница 716: ...15 50 MELSEC Q 15 TROUBLESHOOTING MEMO ...
Страница 724: ...Appendix 8 MELSEC Q APPENDICES Axis address mm inch degree pulse Axis address mm inch degree pulse ...
Страница 725: ...Appendix 9 MELSEC Q APPENDICES MEMO ...
Страница 731: ...Appendix 15 MELSEC Q APPENDICES Initial value Axis 1 Axis 2 Axis 3 Axis 4 Remarks 0 0 0 0 1 1 0 0 0 0 0 0 300 11 0 0 ...
Страница 875: ...Appendix 159 MELSEC Q APPENDICES Appendix 14 External dimension drawing 1 QD75P1N Unit mm 23 4 27 4 98 90 46 ...
Страница 876: ...Appendix 160 MELSEC Q APPENDICES 2 QD75P2N Unit mm 23 27 4 90 4 98 46 3 QD75P4N 23 27 4 90 4 98 46 Unit mm ...
Страница 877: ...Appendix 161 MELSEC Q APPENDICES 4 QD75D1N 12 90 23 27 4 Unit mm 98 4 46 5 QD75D2N 90 23 27 4 12 98 4 46 Unit mm ...
Страница 878: ...Appendix 162 MELSEC Q APPENDICES 6 QD75D4N 90 23 27 4 12 98 4 46 Unit mm ...
Страница 879: ...Appendix 163 MELSEC Q APPENDICES 7 QD75P1 QD75P2 QD75P4 27 4 23 98 90 4 46 unit mm ...
Страница 880: ...Appendix 164 MELSEC Q APPENDICES 8 QD75D1 QD75D2 QD75D4 27 4 23 90 12 98 4 46 unit mm ...
Страница 893: ...WARRANTY ...
Страница 895: ......