3. POSITIONING SIGNAL
3
−
6
(2) Positioning completed signal (M1601+20n)
(a) This signal comes ON when positioning control of the axis designated by
the DSFRP/SVST instruction in the sequence program is completed.
It does not come ON when positioning control is started, or stopped part
way through, due to a zeroing, JOG operation, manual pulse generator
operation, or speed control.
It does not come on when positioning is stopped part way through.
It can be used, for example, to read an M-code on completion of positioning.
(See Section 8.2.)
(b) The positioning completed signal goes OFF at the leading edge (OFF
→
ON)
of the end signal OFF command (M1804+20n), or when a positioning
control start is completed.
At the leading edge (OFF
ON) of the end signal OFF command (M1804+20n)
When the next positioning control start is completed
DSFRP/SVST instruction
Start reception flag
(M2001+n)
Positioning completed
signal (M1600+20n)
End signal OFF command
(M1804+20n)
DSFRP/SVST instruction
Start reception flag
(M2001+n)
Positioning completed
signal (M1600+20n)
ON
OFF
OFF
OFF
t
V
ON
ON
t
V
ON
ON
Dwell time
Dwell time
Positioning
completed
OFF
Positioning start
OFF
Downloaded from