7. POSITIONING CONTROL
7
−
112
(Reverse direction)
5000
5000
10000
5000
10000
(Reverse direction)
Axis 1 positioning
direction
(Forward direction)
Axis 2 positioning direction
(Forward direction)
Axis 3 positioning direction
(Forward direction)
Axis 4 positioning direction
(Forward direction)
10000
Fig. 7.32 Positioning by 4-Axes Constant-Speed Control
(c) Positioning conditions
1) The constant-speed control conditions are shown below.
Item
Setting
Servo program
number
506
Positioning speed
10000
Positioning method
4-axes linear
interpolation
4-axes linear interpolation
4-axes linear
interpolation
Axis 1
3000
5000
5000
Axis 2
4000
3500
3500
Axis 3
4000
−
4000
3000
Pass point
Axis 4
4000
−
6000
6000
2) Constant-speed control start command........ leading edge of X000
(OFF
→
ON)
Downloaded from