8. AUXILIARY AND APPLIED FUNCTIONS
8
−
15
8.7 Skip
Function
Based on an external input, the skip function halts the current positioning and
executes the next positioning control.
The servo system CPU can run the skip function according to the external STOP
signal and the sequence program.
(1) The procedure for using the skip function based on the external STOP signal
and the sequence program is shown below.
Start
Start positioning with servo
program
Turn ON external STOP signal
when positioning halts.
Turn On the STOP input
valid/invalid signal (M1809+20n)
After deceleration stop, start next
servo program positioning
End
Positioning does not start if the STOP signal, stop command
(M1800+20n), or rapid stop command (M1801+20n) is ON.
Turn M1809+20n ON to use the skip function.
(The external STOP signal becomes invalid when the next
positioning starts.)
Operation stop confirmed when start accept flag (M2001+n)
turns OFF.
(2) Operation timing
The operation timing of the skip function is shown in the diagram below.
PLC ready(M2000)
OFF
OFF
OFF
OFF
ON
ON
All axes servo start command
(M2042)
External STOP signal
Turn ON STOP input valid/invalid
signal (M1809+20n) at start of
positioning.
V
A
Start
positioning
to point A
Positioning to point A
Deceleration stop due to STOP input
ON before next positioning starts
Start positioning of the next servo program
due to skip
function
(STOP signal turning ON is ignored
while M1809+20n is ON)
ON
ON