![Mitsubishi Electric A171SHCPUN Скачать руководство пользователя страница 371](http://html.mh-extra.com/html/mitsubishi-electric/a171shcpun/a171shcpun_programming-manual_238566371.webp)
APPENDICES
APP
−
53
A172SHCPUN
A171SHCPUN
Device
Number
Signal Name
Signal
Direction
Refresh
Cycle
Fetch Cycle
Device
Number
Signal Name
Signal
Direction
Refresh
Cycle
Fetch Cycle
D1008
D1008
D1009
D1009
Limit switch output disable
setting register (2 points)
SCPU
→
PCPU
3.5ms
D1010
D1010
D1011
Limit switch output disable
setting register (4 points)
3.5ms
D1011
Unusable (2 points)
D1012
Setting Register for a axis
number controlled with
manual pulse generator 1
SCPU
→
PCPU
Manual pulse
generator
operation enabled
D1012
Setting Register for a axis
number controlled with
manual pulse generator 1
SCPU
→
PCPU
Manual pulse
generator
operation enabled
D1013
D1013
D1014
Unusable (2 points)
D1014
Unusable (2 points)
D1015
JOG operation simultaneous
start axis setting register
At driving
D1015
JOG operation
simultaneous start axis
setting register
At driving
D1016
Axis 1
D1016
Axis 1
D1017
Axis 2
D1017
Axis 2
D1018
Axis 3
D1018
Axis 3
D1019
Axis 4
D1019
Axis 4
1 pulse input
modification setting
register for manual
pulse generator (4
points)
SCPU
→
PCPU
Manual pulse
generator
operation enabled
D1020
Axis 5
D1020
D1021
Axis 6
D1021
D1022
Axis 7
D1022
D1023
Axis 8
1 pulse input
modification setting
register for manual
pulse generators
(8 points)
SCPU
→
PCPU
Manual pulse
generator
operation enabled
D1023
Unusable (4 points)
(9) Special relays
Device number
Signal name
Signal
direction
Refresh cycle
Fetch cycle
M9073
PCPU WDT error flag
M9074
PCPU ready completion flag
M9075
Test mode flag
M9076
External rapid stop input flag
M9077
Manual pulse generator axis setting
error flag
M9078
Test mode request error flag
M9079
Servo program setting error flag
SCPU
←
PCPU
END
(10) Special registers
Device number
Signal name
Signal
direction
Refresh cycle
Fetch cycle
M9180
D9181
D9182
D9183
Limit switch output status
3.5ms
D9184
PCPU WDT error factor
At PCPU WDT error
occurrence
D9185
D9186
Servo amplifier type
Power ON
D9187
Manual pulse generator axis setting
error information
Manual pulse generator
operation enabled
D9188
Test mode request error information
Test mode request
D9189
Error program number
D9190
Error item information
Start
D9191
Servo amplifier installation information
SCPU
←
PCPU
Power ON, 10ms
D9192
Manual pulse generator 1 smoothing
magnification setting register
SCPU
→
PCPU
Manual pulse
generator
operation
enabled
D9193
Unusable
D9194
Unusable
D9195
Unusable
D9196
PC link communication error code
SCPU
←
PCPU
3.5ms
D9197
Unusable
D9198
Unusable
D9199
Unusable
* The entry "END" in the Refresh Cycle column indicates 80ms or a longer sequence program scan time.