1. GENERAL DESCRIPTION
1
−
4
1.1.2
System configuration precautions
The following table summarizes the notes on system configuration, system setup
items, and relative checks that differ from those of the A171SCPU.
Product
Name
Module
Name
Number of
Available
Modules
System Setup Item
Relative
Check
Notes and Remarks
1. MR-J2-B allows the use of the following
motors with high-resolution encoders.
•
HC-MF***W1 (32768PLS)
•
HA-FF***W1 (32768PLS)
•
HC-SF**2W2 (131072PLS)
2. [Allowable travel value during power-off]
When ABS motor is used, set the
allowable travel value during servo
amplifier power-off by rpm (rotations per
minute).
This setting value is used for checking
when the servo amplifier is switched ON.
Setting range
Default value
0 to 16383 (rpm)
10 (rpm)
Separated
servo
amplifier
MR-J2S-B
MR-J2-B
MR-H-BN
• Max. 8 axes for
A172SHCPUN
• Max. 4 axes for
A171SHCPUN
•
Connect the servo
amplifier to the
'SSCNET1'
interface.
•
The setting range
changes for high-
resolution encoder
support.
1. External signals
(1) Set the axis numbers of external
signals FLS, RLS, STOP, and
DOG/CHANGE for A172SENC CTRL
connector signals PX0 to PX1F.
Axes need not be set unless they are
used by external signals.
CPU unit
Setting range
Default value
A172SHCPUN
Set axes 1 to 8 for
PX0 to PX1F.
Axes 1 to 8
are set.
A171SHCPUN
Set axes 1 to 4 for
the first half (PX0
to PX0F).
Axes 1 to 4
are set.
Manual pulse
generator
/synchronous
encoder
interface
module
A172SENC
1
•
The same
axis
number
must not be
set.
•
The external signal
setup window has
been improved for
a better
understanding.
•
The conventional
A171SENC can
also be used for
A171SHCPUN and
A172SHCPUN.
However, it must
be set as
A172SENC during
system setting.
Man/machine
control
module
A271DVP
0
Not available. Settings cannot be made.
1. Set the number of points and the starting
I/O number for PC CPU I/O modules to be
mounted on the motion extension base
unit.
The number to be set must not precede
the I/O numbers for use by the PLC
extension base unit.
CPU unit
Effective
setting range
Default value
A172SHCPUN
X/Y0
∼
X/Y3FF
A171SHCPUN
X/Y0
∼
X/Y1FF
PLC CPU
I/O module
(motion slot)
A1SX
A1SY
A1SH42
Up to 128 I/O
points (total)
•
The total
number of
points must
be less than
or equal to
256.
•
The starting
I/O number
plus number
of occupied
points must
be less than
or equal to
X/Y800.
•
Though settings
can be made within
a range of X/Y0 to
X/Y7FF, they must
be made in the
range defined in the
left-hand column.
A1S68B
A1S65B
1 stage
•
Use this unit for
systems capable of
one-stage extension.
PLC
extension
base unit
A168B
1 stage
•
Use this unit for
bus connection
GOT.