![Mitsubishi Electric A171SHCPUN Скачать руководство пользователя страница 269](http://html.mh-extra.com/html/mitsubishi-electric/a171shcpun/a171shcpun_programming-manual_238566269.webp)
7. POSITIONING CONTROL
7
−
117
POINTS
The fixed acceleration/deceleration method is a type of acceleration/
deceleration processing whereby even if the command speed changes, the
time taken up by acceleration/deceleration remains fixed.
t
Fixed acceleration/
deceleration time.
V
(1) When the fixed acceleration/deceleration method is used, the following
processing and parameters are invalidated.
•
Rapid stop deceleration time in parameter block
•
Completion point designation method for speed change point
•
"S" curve acceleration/deceleration
(2) When the type of positioning operation shown below (constant speed
control) is performed, the speed processing for each axis is as shown
below.
Positioning operation
X
Y
Axis 1
Axis 2
Ay
Ax
Constant speed control processing of each axis
Address Ax
Address Ay
Axis 1
Axis 2
V
V
t
t
Ax
Ay