![Mitsubishi Electric A171SHCPUN Скачать руководство пользователя страница 24](http://html.mh-extra.com/html/mitsubishi-electric/a171shcpun/a171shcpun_programming-manual_238566024.webp)
1. GENERAL DESCRIPTION
1
−
10
[Executing JOG Operation with a Servo System CPU]
The servo system CPU can be used to perform JOG operation on a designated
axis in accordance with a sequence program.
An overview of JOG operation is presented below.
Servo System CPU System
Request for
execution of JOG
operation
(M1802)
M2001
M10
JOG speed setting command
Interlock signal for axis 1
JOG speed setting
Setting of "JOG speed setting
completed flag"
M1803
Forward JOG exe-
cution command
Reverse JOG execution
command (for interlock)
Switchs the forward JOG
execution command (M1802)
ON/OFF
DMOVP K1000
D964
SET M10
Sequence program
Created and modified using a
peripheral device
(Note)
SCPU Control
In the sequence program, after setting the JOG speed, turn the
JOG operation execution flag (M1802/M1803) ON.
(1) Set the positioning control parameters using a peripheral device.
(2) Using the sequence program, set the JOG speed in the JOG operation speed
setting register for each axis.
(3) JOG operation is executed while the JOG operation execution flag is kept ON
by the sequence program.
Downloaded from