![Mitsubishi Electric A171SHCPUN Скачать руководство пользователя страница 344](http://html.mh-extra.com/html/mitsubishi-electric/a171shcpun/a171shcpun_programming-manual_238566344.webp)
APPENDICES
APP
−
26
2.5
PC Link Communication Errors
Table 2.15 PC Link Communication Error Codes
Error Codes
Stored in D9196
Error Description
Action to Take
01
A receiving packet for PC link
communication does not arrive.
The arrival timing of the receiving
packet is too late.
•
Check whether the PC has been switched
ON.
•
Check whether the communication cable
has been connected firmly.
•
Check whether the communication cable
has been broken.
•
Check whether the A30BD-PCF or A30CD-
PCF has been mounted normally.
02
A receiving packet CRC code is
invalid.
•
Check whether there is a noise source near
the PC.
•
Check whether the communication cable
has been connected firmly.
•
Check whether the communication cable
has been broken.
03
A receiving packet data ID is
invalid.
•
Check whether the A30BD-PCF or A30CD-
PCF has been mounted normally.
•
Replace the A30BD-PCF or A30CD-PCF.
04
The number of received frames is
invalid.
•
Check whether the communication cable
has been connected firmly.
•
Check whether the communication cable
has been broken.
•
Check whether there is a noise source near
the PC.
05
A PC communication task is not
active yet.
•
Start the PC communication task.
Downloaded from