65
The outline of each mode is as follows.
(1) Simple comparison mode
A set value and measured value are compared and whenever the comparative result satisfies the
condition, the output turns on. When the gate control etc., are required, PLC etc., are needed.
As for the comparison and the judgement condition, refer to each paragraph in [9-3.Simple
comparison mode].
(2) Sequential mode
The comparison of the measured value without connecting PLC, etc., outside, and the control that
sets up the order of the gate control etc., can be worked.
As a result, system construction that omits PLC becomes possible.
In this mode, each output is turned ON, according to the value of each brand set with the on edge
(OFF
→
ON) of start signal. If the set value is compared with the measurement value, and the
comparison result satisfies it, then the output becomes OFF.
If the output is turned OFF once in this mode, the output is turning off until the completion signal is
output, even when the comparison results become out of the condition.
Refer to each paragraph of in [9-4.Sequential mode].
In this mode, you can control in order without connecting the sequencer etc. externally.
(3) 4 steps comparator mode 1
Compare a set value and the measured value, and output the comparative result.
With four steps comparator modes 1, Turning ON or OFF the output is decided on the condition of
[Under] or [Over] after comparing with a measuring value and the set value 1.
Please refer to each clause of [Clause 9-5] for more information about movement.
(4) 4 steps comparator mode 2
With four steps comparator mode 2, it is suitable for sorting measurements because the output twins
on when a measurement value enters within two set points.
Please refer to each clause of [Clause 9-6] for more information about movement.
Содержание CSD-903-EX
Страница 1: ...DIGITAL INDICATOR CSD 903 EX Instruction Manual EN294 1492 H ...
Страница 2: ...IV ...
Страница 91: ...75 ...
Страница 93: ...77 ...
Страница 95: ...79 ...
Страница 97: ...81 ...
Страница 129: ...113 14 4 Connecting method 14 4 1 One to one RS 485 RS 485 S G A B address 00 S G RS 485 host CSD 903 ...
Страница 199: ...183 Inform us about the contents of failure and situation at site in details ...
Страница 204: ...188 Inform us about the contents of failure and situation at site in details ...
Страница 206: ...190 Inform us about the contents of failure and situation at site in details ...
Страница 209: ...193 Inform us about the contents of failure and situation at site in details ...
Страница 224: ... ...
Страница 225: ......