162
Item
Function No. Number
Set value of Return command
Sub display section
70 19
0: OFF
1: A Brand (1 digit) / Accumulation times
(6 digits) / Accumulation value (8 digits)
2: B Brand (1 digit) / Accumulation times
(6 digits) / Last accumulated data (6 digits)
3: C Brand (1 digit) / Last accumulated data
(6 digits) / Accumulation value (8 digits)
4: D Brand (1 digit) / Last accumulated data
(6 digits) / OK (6 digits)
5: E Brand (1 digit) / Accumulation times
(6 digits) / OK (6 digits)
6: F Brand (1 digit) / OK (6 digits) / Accumulation
value (8 digits)
7: G Brand (1 digit) / Near zero (6 digits) / Full
(6
digits)
8: OK (6 digits) / Over (5 digits) / Under (5 digits)
9: I Brand (1 digit) / OK (6 digits) / Free fall
(6
digits)
10: J Brand (1 digit) / S1 (6 digits) / S2 (6 digits)
11: K Brand (1 digit) / S1 (6 digits) / S3 (6 digits)
12: L Brand (1 digit) / S1 (6 digits) / S4 (6 digits)
13: M Brand (1 digit) / S2 (6 digits) / S3 (6 digits)
14: N Brand (1 digit) / S2 (6 digits) / S4 (6 digits)
15: O Brand (1 digit) / S3 (6 digits) / S4 (6 digits)
16: P Brand (1 digit) / OK (6 digits)
17: Q Brand (1 digit) / Over (5 digits) / Under
(5
digits)
18: R Brand (1 digit) / Accumulation times (6 digits)
19: S Brand (1 digit) / Accumulation value
(10
digits)
20: T Brand (1 digit) / Last accumulated data
(6
digits)
Brand setting target on
comparator
70 20
0 ~ 7
Operation target on 4 steps
comparator
70 21
0000 ~ 1111 (0 : Display interlock, 1 : Gross, 2 : Net)
10
0
digit : Operation target of comparator S1
10
1
digit : Operation target of comparator S2
10
3
digit : Operation target of comparator S3
10
4
digit : Operation target of comparator S4
Operation condition on
4-steps comparator
70 22
0000 ~ 1111 (0 :OFF, 1 : More than, 2 : Less than)
10
0
digit : Operation condition of comparator S1
10
1
digit : Operation condition of comparator S2
10
3
digit : Operation condition of comparator S3
10
4
digit : Operation condition of comparator S4
Operation condition on 4-
steps comparator S0
70 23
0 : Always OFF
1 : On when both of S1 and S2 output are OFF
2 : On when both of S1 and S3 output are OFF
3 : On when both of S1 and S4 output are OFF
4 : On when both of S2 and S3 output are OFF
5 : On when both of S2 and S4 output are OFF
6 : On when both of S3 and S4 output are OFF
7 : On when (Gross weight)
≧
(Weighing capacity)
Comparator hysteresis
operating conditions
70 24
0 : On delay, 1 : Off delay
Width of comparator
hysteresis data
70 25
00 ~ 99 (Unit : 1D)
Width of comparator
hysteresis time
70 26
00 ~ 99 (Unit : 0.1 s)
Please change [7*] of above mentioned command to [8*] about the command at the time of
writing.
Содержание CSD-903-EX
Страница 1: ...DIGITAL INDICATOR CSD 903 EX Instruction Manual EN294 1492 H ...
Страница 2: ...IV ...
Страница 91: ...75 ...
Страница 93: ...77 ...
Страница 95: ...79 ...
Страница 97: ...81 ...
Страница 129: ...113 14 4 Connecting method 14 4 1 One to one RS 485 RS 485 S G A B address 00 S G RS 485 host CSD 903 ...
Страница 199: ...183 Inform us about the contents of failure and situation at site in details ...
Страница 204: ...188 Inform us about the contents of failure and situation at site in details ...
Страница 206: ...190 Inform us about the contents of failure and situation at site in details ...
Страница 209: ...193 Inform us about the contents of failure and situation at site in details ...
Страница 224: ... ...