168
Item Function
No.
Number
Contents
Weighing mode
72 01
0 : Simple comparison mode
1 : Sequential mode
2 : 4 steps comparator mode 1
3 : 4 steps comparator mode 2
Control mode
72 02
0 : Batch mode, 1 : Discharge mode,
2 : External input changeover
Comparison signal operation
72 05
0 : ANYTIME, 1 : IN STABLE MODE,
2 : SYNC. WITH BATCH FIN,
3 : BATCH FIN.+HOLD
Near zero comparison operation
72 06
0 : Gross, 1 : Net, 2 : OFF, 3 : |Gross|,
4 : |Net|
Full comparative operation
72 07
0 : Gross, 1 : Net, 2 : OFF, 3 : |Gross|,
4 : |Net|
Batch Monitoring Timer
72 10
0000 ~ 9999 (Unit : 1 s)
Start above near zero at the time
of batch start
72 15
0 : Invalid, 1 : Effective
Automatic tare at the time of
batch start
72 16
0 : Invalid, 1 : Effective
Batch start delay timer
72 17
0000 ~ 9999 (Unit : 1 s)
Automatic tare after batch start
delay timer
72 18
0 : Invalid, 1 : Effective
F-flow compare stop timer
72 20
0000 ~ 9999 (Unit : 0.01 s)
M-flow compare stop timer
72 21
0000 ~ 9999 (Unit : 0.01 s)
D-flow compare stop timer
72 22
0000 ~ 9999 (Unit : 0.01 s)
Automatic free fall compensation
72 25
0 : Invalid, 1 : Effective
Width for the automatic free fall
compensation
72 26
00000 ~ 99999 (Unit : 1D)
The command of writing is changing the upper commands [7*] to [8*].
Содержание CSD-903-EX
Страница 1: ...DIGITAL INDICATOR CSD 903 EX Instruction Manual EN294 1492 H ...
Страница 2: ...IV ...
Страница 91: ...75 ...
Страница 93: ...77 ...
Страница 95: ...79 ...
Страница 97: ...81 ...
Страница 129: ...113 14 4 Connecting method 14 4 1 One to one RS 485 RS 485 S G A B address 00 S G RS 485 host CSD 903 ...
Страница 199: ...183 Inform us about the contents of failure and situation at site in details ...
Страница 204: ...188 Inform us about the contents of failure and situation at site in details ...
Страница 206: ...190 Inform us about the contents of failure and situation at site in details ...
Страница 209: ...193 Inform us about the contents of failure and situation at site in details ...
Страница 224: ... ...
Страница 225: ......