6-11. Clear at power on
Setting of the clear at power on is selected by C function CF-18.
Clear at power on function is clear [Data of tare weight cancellation],
[Data of preset tare weight cancellation] and [Data of zero set and zero tracking] when the power is
turn on, or in the operation of display turning on.
Setting: 000 ~ 111, 0: Invalid, 1: effective, Default: 000
10
0
: Data of tare weight cancellation
10
1
: Data of preset tare weight cancellation
10
2
: Data of zero set and zero tracking
6-12. Setting while set mode 2 or set of preset tare
Proceed to set the unit display in sub-display section and the stability detections in condition display
while the set mode 2 or set of preset tare.
6-12-1. Operation for stability detection
The selection whether the stability detection is effective or invalid is made by C function CF-20.
Default is set to [Invalid].
6-12-2. Operation for unit display in sub-display section
The selection whether the unit display in sub-display section is effective or invalid is made by C
function CF-21. Default is set to [Invalid].
6-13. Gravity acceleration compensation
When the calibration place and the using place of the measuring are different, the error is caused in
span by the difference of the gravity acceleration of the various place districts.
The gravity acceleration compensation function is a function for the compensation of this span error
by setting the gravity acceleration of two districts with a different calibration place and using place.
When the calibration place and the using place are the same, it is not necessary to execute the
gravity acceleration compensation.
6-13-1. Setting method of gravity acceleration compensation
The setting method of the gravity acceleration compensation is selected by C function CF-25.
[The district number is set] or [The numerical value of gravity acceleration is set] can be selected.
Default is set to [The district number is set].
6-13-2. Setting of district number of the using place (When CF-25: 0)
The setting of the district number of the using place is executed by C function CF-26.
The setting of district number: 01 ~ 16
Default is set to 10 districts.
Please refer to [Gravity acceleration compensation table] in the next page.
6-13-3. Setting of district number of the calibration place (When CF-25: 0)
The district number of the calibration place can be set by C function CF-27.
The set of the district number: 01 ~ 16
Default is set to 10 districts.
Please refer to [Gravity acceleration compensation table] in the next page.
Содержание CSD-903-EX
Страница 1: ...DIGITAL INDICATOR CSD 903 EX Instruction Manual EN294 1492 H ...
Страница 2: ...IV ...
Страница 91: ...75 ...
Страница 93: ...77 ...
Страница 95: ...79 ...
Страница 97: ...81 ...
Страница 129: ...113 14 4 Connecting method 14 4 1 One to one RS 485 RS 485 S G A B address 00 S G RS 485 host CSD 903 ...
Страница 199: ...183 Inform us about the contents of failure and situation at site in details ...
Страница 204: ...188 Inform us about the contents of failure and situation at site in details ...
Страница 206: ...190 Inform us about the contents of failure and situation at site in details ...
Страница 209: ...193 Inform us about the contents of failure and situation at site in details ...
Страница 224: ... ...
Страница 225: ......