SPECIFICATIONS

Cat. No. ..................................................... 3622-20 

Volts

.............................................................. 12 DC

Battery Type .................................................M12™

Charger Type................................................M12™

Laser............................................................Class 2

Lines Max Power ................................. P

AVG

 ≤ 7 mW

Points Max Power................................ P

AVG

 ≤ 1 mW

Pulse Frequency..........................................10 KHz

Pulse Duration Normal Mode ................. T

p

 ≤ 80 µs

Pulse Duration Power Save.................... T

p

 ≤ 50 µs

Wavelength.......................................... 510-530 nm

Lines Beam Divergence ................................. 1 rad

Points Beam Divergence .......................... 0.5 mrad

Storage Temp ....................................-4°F to 120°F

Working Range .................................................125'

Range with Detector .........................................165'

Accuracy ...............................................

±1/8" @ 33'

Settle Time ......................................... < 3 Seconds

Tripod Mount ..................................

1/4"-20, 5/8"-11

Ingress Protection............................................ IP54

Drop Rating .......................................................1 m

Leveling ............Auto ±°4 side to side, front to back

Recommended Ambient 

   Operating Temperature .................. 14°F to 104°F

FUNCTIONAL DESCRIPTION

1. Laser apertures

2. Laser mode indicator

3. 

On/Off dial

4. Pivot Bracket

3

4

7

5

1

6

Milwaukee Tool, Brookfield, WI 53005 USA

CROSS LINE & PLUMB POINTS 

LASER 

CAT. NO. 3622-20              12 V                        SER. 

Made in China

WARNING               AVERTISSEMENT               ADVERTENCIA

    To reduce the risk of injury, user must read operator's manual. Use M12  batteries.

      Pour minimiser les risques de blessures, l'utilisateur doit lirele manual. Utiliser des piles M12 .

        Para reducir el riesgo de lesiones, 

          el usuario debe leer el manual. 

            Utilice baterías de M12 . 

IEC 60825-1:2014-05   t

P

 ≤ 80 μs MAX OUTPUT 

P

AVG

 ≤ 7mW @ 510nm - 530nm LINES

P

AVG

 ≤ 1mW @ 510nm - 530nm POINTS

COMPLIES WITH 21 CFR 1040.10 AND 1040.11 

EXCEPT FOR CONFORMANCE WITH IEC 60825-1 

ED. 3., AS DESCRIBED IN LASER NOTICE NO. 56, 

DATED MAY 8, 2019. THIS DEVICE COMPLIES  

WITH PART 15 OF THE FCC RULES. OPERATION IS 

SUBJECT TO THE FOLLOWING TWO CONDITIONS: 

(1) THIS DEVICE MAY NOT CAUSE HARMFUL 

INTERFERENCE, AND (2) THIS DEVICE MUST 

ACCEPT ANY INTERFERENCE RECEIVED, 

INCLUDING INTERFERENCE THAT MAY CAUSE 

UNDESIRED OPERATION.

2

1

1

1

5. Micro adjust

6. Fuel gauge

7. 

Mode button

8

10

9

8. 

Threaded inserts

9. Magnets

10. 

Nail/Screw hole

SYMBOLOGY

 

 

Volts

 

 

Direct Current

  

LASER RADIATION

   DO NOT STARE INTO BEAM

 

 

CLASS 2 LASER PRODUCT

 

 

Magnets

 

 

Read operator’s manual

ASSEMBLY

WARNING

Recharge only with the charger 

specified for the battery. For spe

-

cific charging instructions, read the operator’s 

manual supplied with your charger and battery.

Removing/Inserting the Battery

To 

remove

 the battery, push in the release buttons 

and pull the battery pack away from the tool.

WARNING

Always remove battery pack before 

changing or removing accessories. 

To 

insert

 the battery, slide the pack into the body 

of the tool. Make sure it latches securely into place.

WARNING

Only use accessories specifically 

recommended for this tool. Others 

may be hazardous.

Power Save

Use power save mode to extend the battery run 

time. Power save mode is indicated by dimmed laser 

beams and the Mode indicator pulsing. Visual range 

is decreased in power save mode. To turn power save 

mode ON or OFF, press and hold Mode button for 3 

seconds. The tool will automatically switch to power 

save mode if less than 7% of battery charge remains.

Fuel Gauge

To determine the amount of charge left in the battery, 

turn the tool 

ON

. The Fuel Gauge will light up for 2-3 

seconds. When less than 10% of charge is left, 1 light 

on the fuel gauge will flash 4 times.

To signal the end of charge, 1 light on the fuel gauge 

will flash 8 times and the tool will not run. Charge 

the battery pack.

If the battery becomes too hot, the fuel gauge lights 

will flash and the tool will not run. Allow the battery 

to cool down.

*When automatically switched to power save mode 

due to low battery, the tool cannot be switched back 

to normal mode until the battery is charged/replaced.

WARNING

To reduce the risk of injury or dam-

age, securely mount/attach the 

laser before starting an operation. Injury/damage 

may occur if the laser falls.

Mounting/Adjusting the Laser Level

The pivot bracket can be used to mount the laser 

level in multiple ways:

• Use the embedded magnets to secure the laser level 

to steel studs, steel beams, etc.

• Use the keyhole slot to hang the laser level on the 

wall with a nail or screw.

• Set the laser level on a flat surface.

Содержание M12 3622-20

Страница 1: ...ator s manual AVERTISSEMENT Afin de r duire le risque de blessures l utilisateur doit lire et bien comprendre le manuel ADVERTENCIAPara reducir el riesgo de lesiones el usuario debe leer y entender el...

Страница 2: ...utside the specified range may damage the battery and increase the risk of fire STORE YOUR BATTERYAND TOOL in a cool dry place Do not store battery where temperatures may exceed 120 F 50 C such as in...

Страница 3: ...l ASSEMBLY WARNING Recharge only with the charger specified for the battery For spe cific charging instructions read the operator s manual supplied with your charger and battery Removing Inserting the...

Страница 4: ...or 5 8 11 threaded insert to mount on a tripod Once the level is mounted use the micro adjustment knobs to fine tune the laser line OPERATION WARNING To reduce the risk of injury or tem porary effects...

Страница 5: ...y adjustment Securely mount the tool on one side of the room and centered between walls A and B Direct the laser lines toward the other side of the room such that the horizontal line appears on both w...

Страница 6: ...tool d 9 The maximum vertical deviation d is dmax 2X H door opening x 1 8 33 Example for a door opening height of 7 the maximum permitted deviation d is dmax 2 x 7 x 1 8 33 0 05 Therefore the measurem...

Страница 7: ...Electric Lever Hand Chain M12 Heated Gear Reconditioned Product and Test Measurement Products There are separate and distinct warranties available for these products The warranty period for Job Site...

Страница 8: ...ntes avec de l eau Si le liquide entre en contact avec les yeux consulter un m decin Le liquide s chappant des batteries peut causer des irritations ou des br lures Ne pas utiliser les blocs piles ni...

Страница 9: ...C 4 F to 120 F Plage de travail 38 m 125 Plage d tecteur 50 m 165 Pr cision 3 mm 1 8 10 m 33 Temps d ajustage 3 secondes Montage sur tr pied 1 4 20 5 8 11 Indice de protection IP54 Coefficient de chut...

Страница 10: ...regarder directe ment dans le laser lorsqu il est allume ATTENTION L usage de controles de reglages ou de procedures ne figurant pas dans ce manuel peut entrainer l exposition a des rayonnements dange...

Страница 11: ...me entre deux murs ou structures A et B est requise Il est aussi conseill de monter le niveau laser sur un tr pied des fins d un ajustage facile 1 Monter fermement l outil une distance approxi mative...

Страница 12: ...centre de la ligne horizontale sur le mur A point III Veuillez prendre soin de que le point III s aligne autant vertical que possible sur le point I ou au dessus du ce point 6 La distance d entre les...

Страница 13: ...istance entre les points I et III sur le plafond est la d viation d de l outil Cette distance ne devra pas d passer 3 mm 1 8 max 10 m 33 Par rapport la distance de mesure de 2 x 5 m 16 5 10 m 33 a d v...

Страница 14: ...D ACHAT DE TOUT PRODUIT MILWAUKEE SI VOUS N ACCEPTEZ PAS CETTE CONDITION VOUS NE DEVEZ PAS ACHETER LE PRODUIT EN AUCUN CAS MILWAUKEE NE SAURAIT TRE RESPONSABLE DE TOUT DOMMAGE ACCESSOIRE SP CIAL OU IN...

Страница 15: ...la posibilidad de que se ocasione interferencia en otros dispositivos ATENCI N El uso de controles o ajustes o el desempe o de los proced imientos que no sean los que se especifican aqu puede provoca...

Страница 16: ...m ticamente a modo ahorro si queda menos de 7 de bater a Indicador de carga Para determinar la cantidad de carga que queda en la bater a encienda la herramienta El medidor de combustible se iluminar d...

Страница 17: ...os especificados Si se almacenan en calor o fr o excesivo permita que transcurran al menos 2 horas para aclimatarse a temperatura ambiente antes de encender la herramienta Si el problema contin a cont...

Страница 18: ...e para un f cil ajuste Monte fijamente la herramienta en un lado de la hab itaci n y centrado entre las paredes A y B Dirija las l neas del l ser hacia el otro lado de la habitaci n de tal forma que l...

Страница 19: ...a medida entre los puntos III y IV en la abertura superior de la puerta no debe exceder 1 3 mm 0 05 en una puerta de 2 1 m 7 Precisi n del punto de plomada Se necesita una distancia de medici n libre...

Страница 20: ...clavadora de broches 23GA M12 la ribeteadora ciega de 6 4 mm 1 4 M18 FUEL con ONE KEY el raspador de neum ticos de baja velocidad M12 FUEL 58143622d3 00658143622Q0 03 A 02 22 Printed in China MILWAUK...

Отзывы: