47
9. Troubleshooting
9.1 Indoor unit error display
For MSX-07HRN1-QC2, MSX-09HRN1-QC2,
MSX-12HRN1-QC2,
MSX-18HRN1-QC2 models:
LED
Failure
E1
EEPROM error
E2
Zero crossing detection error
E3
Indoor fan speed has been out of control
E4
Over current protection occurs 4 times.
E5
The T1 sensor is open circuit or short circuit
E6
The T2 sensor is open circuit or short circuit
For MSX-21HRN1-QB8W, MSX-24HRN1-QB8W
models:
LED
Failure
E1
EEPROM error
E4
Over current protection occurs 4 times.
E5
The T1 sensor is open circuit or short circuit
E6
The T2 sensor is open circuit or short circuit
E7
The T3 sensor is open circuit or short circuit
E9
Indoor / outdoor units communication error