9-6
MS-890 Industrial Automation Scanner
User Manual
Configuration Database
Configuration Database
Configuration Database by Serial Command
Note:
You can also set
Focus
,
Gain Settings
,
Tracking Adjustment
,
Scan Speed
,
Laser Framing
, and
Background Color
individually.
0
= Inactive Input State
1
= Active Input State
Important:
Control Trigger 3
uses the
External Trigger
input. When this
input is active, there is no external trigger available to the scanner. Therefore,
when Control Trigger 3 is active and
External Trigger Mode
is selected, a
read cycle will be triggered by an active input from any of the control trigger
inputs.
Since an active state on one of the control inputs is required to trigger a
read cycle, sequence “000” would not be valid. When Control Trigger 3 is
active, the sequence starts at “001”. This allows a maximum of
7
accessible database settings. When Control Trigger 3 is not active, the
sequence starts with all active inputs disabled.
Definition:
The
Configuration Database
allows the user to save multiple scanner
configuration settings. The database can be used to save the most com-
monly used configurations, making the scanner easily adaptable to changing
applications, or it can be used in conjunction with
Optoelectric Control
, to
change configurations dynamically.
When
Optoelectric Control
is set to
Control Trigger (Optoelectric Control
Mode)
, the first seven indexes can be switched by external inputs. Each
database configuration setting is assigned to a control trigger sequence.
The table below illustrates the relationship between control trigger
sequence and database indexes.
Active Trigger(s) = 1, 2, 3 Active Trigger(s) = 1, 2
Active Trigger(s) = 1
Control Triggers
Control Triggers
Control Triggers
Index
3
2
1
3
2
1
3
2
1
1
0
0
1
Disabled
0
0
Disabled Disabled
0
2
0
1
0
0
1
1
3
0
1
1
1
0
N/A
4
1
0
0
1
1
N/A
5
1
0
1
N/A
N/A
N/A
6
1
1
0
N/A
N/A
N/A
7
1
1
1
N/A
N/A
N/A
Serial Cmd:
<
K227,
database index,focus position,gain,tracking,AGC mode,raster
top,raster bottom,raster speed,laser framing status,laser on position,laser
off position,laser power, background color
>
Содержание MS-890
Страница 1: ...MS 890 Industrial Automation Scanner User Manual P N 84 000890 Rev B...
Страница 12: ...xii MS 890 Industrial Automation Scanner User Manual Statement of RoHS Compliance...
Страница 26: ...1 14 MS 890 Industrial Automation Scanner User Manual Save Configuration in ESP...
Страница 44: ...2 18 MS 890 Industrial Automation Scanner User Manual Send Receive Options...
Страница 94: ...4 24 MS 890 Industrial Automation Scanner User Manual Tracking Adjustment...
Страница 122: ...5 28 MS 890 Industrial Automation Scanner User Manual Autodiscriminate...
Страница 154: ...6 32 MS 890 Industrial Automation Scanner User Manual Quality Output...
Страница 168: ...7 14 MS 890 Industrial Automation Scanner User Manual Mismatch Replace...
Страница 202: ...9 22 MS 890 Industrial Automation Scanner User Manual Calibration by Embedded Menu...
Страница 212: ...10 10 MS 890 Industrial Automation Scanner User Manual Raster Laser by Embedded Menu...
Страница 240: ...12 22 MS 890 Industrial Automation Scanner User Manual Scanner Status Requests...
Страница 262: ...14 8 MS 890 Industrial Automation Scanner User Manual Wiring Box PCB with Connectors Wiring Box PCB with Connectors...
Страница 263: ...MS 890 Industrial Automation Scanner User Manual 14 9 Wiring Box Mounting Plate IB 890 Wiring Box Mounting Plate...
Страница 264: ...14 10 MS 890 Industrial Automation Scanner User Manual Mounting Plate...
Страница 308: ...A 44 MS 890 Industrial Automation Scanner User Manual Glossary of Terms...