MS-890 Industrial Automation Scanner User Manual
A-11
Appendices
Master Symbol Database Size
<
K224,
number of master symbols
>
New Master Pin
<
K225,
status
>
Configuration Database
<
K227,
database index,focus position,gain,tracking,AGC
mode,raster top,raster bottom,raster speed,laser framing status,
laser on position, laser off position,laser power,background
color
>
Sequential Step
<
K228,
sequence step
>
Enter/Delete Master Symbol Data
<
K231,
master symbol number,master symbol data [no data will
delete current master symbol data]
>
Request Master Symbol Data
<
K231,?
>
[for all]
or <
K231,
master symbol number
?
>
Match Replacement Message
<
K735,
status,match replacement message
>
Mismatch Replacement Message
<
K736,
status,mismatch replacement message
>
Diagnostics
Warning Message Status
<
K400,
warning message status,laser high status,laser low
status,NOVRAM/reset warning status
>
Lifetime Hours
<
K401,
hours10,message
>
High Temperature
<
K402,
degrees,message
>
Low Temperature
<
K403,
degrees,message
>
Power-On/Resets Counts
<
K406?
>
returns: power-ons,resets (Read-Only)
Hours Since Last Reset
<
K407?
>
returns: hours,minutes (Read-Only)
Present Operating Temperature
<
K408?
>
returns: current operating temp. (Read-Only)
Service Message
<
K409,
status,message,time,resolution
>
Laser Current Warning
<
K411,
high current status,high current message,low current
warning, low current message
>
Calibration / Configuration Database
Optoelectric Control
<
K226,
mode,# active database settings,latch on trigger,timer/switch
value,control trigger 1 status,control trigger 2 status,control trigger
3 status,database cycles
>
Configuration Database
<
K227,
database index,focus position,gain,tracking,AGC
mode,raster top,raster bottom,raster speed,laser framing status,
laser on position, laser off position,laser power, background
color
>
Save Configuration Database
<
K227+,
database index>
Load Configuration Database
<
K227-,
database index
>
Request Configuration Database
<
K227?,
database index
> or <
K227?
> for entire database.
Advanced Calibration
<
K510,
auto range,starting focus position,focus step size
>
Raster/Laser
Raster
<
K506,
raster status,top offset,bottom offset,raster sweep
rate,read cycle on/off>
Laser On/Off
<
K700,
laser on/off status,laser framing status,laser on position,laser
off position, laser power
>
Output Format
Format Extract
<
K740,
output index,start location,length
>
Содержание MS-890
Страница 1: ...MS 890 Industrial Automation Scanner User Manual P N 84 000890 Rev B...
Страница 12: ...xii MS 890 Industrial Automation Scanner User Manual Statement of RoHS Compliance...
Страница 26: ...1 14 MS 890 Industrial Automation Scanner User Manual Save Configuration in ESP...
Страница 44: ...2 18 MS 890 Industrial Automation Scanner User Manual Send Receive Options...
Страница 94: ...4 24 MS 890 Industrial Automation Scanner User Manual Tracking Adjustment...
Страница 122: ...5 28 MS 890 Industrial Automation Scanner User Manual Autodiscriminate...
Страница 154: ...6 32 MS 890 Industrial Automation Scanner User Manual Quality Output...
Страница 168: ...7 14 MS 890 Industrial Automation Scanner User Manual Mismatch Replace...
Страница 202: ...9 22 MS 890 Industrial Automation Scanner User Manual Calibration by Embedded Menu...
Страница 212: ...10 10 MS 890 Industrial Automation Scanner User Manual Raster Laser by Embedded Menu...
Страница 240: ...12 22 MS 890 Industrial Automation Scanner User Manual Scanner Status Requests...
Страница 262: ...14 8 MS 890 Industrial Automation Scanner User Manual Wiring Box PCB with Connectors Wiring Box PCB with Connectors...
Страница 263: ...MS 890 Industrial Automation Scanner User Manual 14 9 Wiring Box Mounting Plate IB 890 Wiring Box Mounting Plate...
Страница 264: ...14 10 MS 890 Industrial Automation Scanner User Manual Mounting Plate...
Страница 308: ...A 44 MS 890 Industrial Automation Scanner User Manual Glossary of Terms...