MS-890 Industrial Automation Scanner
User Manual
6-25
I/O Parameters
Trend Analysis Mode
Mismatch
Output will be activated when the number of mismatches equals the value entered for
Number to Output On
within the trigger window selected in
Number of Triggers
.
No Read
Output will be activated when the number of No Reads equals the value entered for
Number to Output On
within the trigger window selected in
Number of Triggers
.
Decodes/Trigger Threshold
Output will be activated when the number of decodes equals the value entered for
Number to
Output On
within the trigger window selected in
Number of Triggers
.
Bad Symbol
Output will be activated when the number of
Bad Symbol
occurrences equals the value
entered for
Number to Output On
within the trigger window selected in
Number of Triggers
.
No Symbol
Output will be activated when the number of
No Symbol
occurrences equals the value
entered for
Number to Output On
within the trigger window selected in
Number of Triggers
.
Definition:
Sets the trend condition (
Mismatch
,
No Read
,
Decodes/Trigger
,
Bad
Symbol
, or
No Symbol
) that will activate the output.
Serial Cmd:
<
K780,
trend analysis mode
,number of triggers,number to output on,
decodes/trigger threshold
>
Default:
No Read
Options:
0 = Mismatch
1 = No Read
2 = Decodes/Trigger Threshold
3 = Bad Symbol
4 = No Symbol
Содержание MS-890
Страница 1: ...MS 890 Industrial Automation Scanner User Manual P N 84 000890 Rev B...
Страница 12: ...xii MS 890 Industrial Automation Scanner User Manual Statement of RoHS Compliance...
Страница 26: ...1 14 MS 890 Industrial Automation Scanner User Manual Save Configuration in ESP...
Страница 44: ...2 18 MS 890 Industrial Automation Scanner User Manual Send Receive Options...
Страница 94: ...4 24 MS 890 Industrial Automation Scanner User Manual Tracking Adjustment...
Страница 122: ...5 28 MS 890 Industrial Automation Scanner User Manual Autodiscriminate...
Страница 154: ...6 32 MS 890 Industrial Automation Scanner User Manual Quality Output...
Страница 168: ...7 14 MS 890 Industrial Automation Scanner User Manual Mismatch Replace...
Страница 202: ...9 22 MS 890 Industrial Automation Scanner User Manual Calibration by Embedded Menu...
Страница 212: ...10 10 MS 890 Industrial Automation Scanner User Manual Raster Laser by Embedded Menu...
Страница 240: ...12 22 MS 890 Industrial Automation Scanner User Manual Scanner Status Requests...
Страница 262: ...14 8 MS 890 Industrial Automation Scanner User Manual Wiring Box PCB with Connectors Wiring Box PCB with Connectors...
Страница 263: ...MS 890 Industrial Automation Scanner User Manual 14 9 Wiring Box Mounting Plate IB 890 Wiring Box Mounting Plate...
Страница 264: ...14 10 MS 890 Industrial Automation Scanner User Manual Mounting Plate...
Страница 308: ...A 44 MS 890 Industrial Automation Scanner User Manual Glossary of Terms...