MS-890 Industrial Automation Scanner
User Manual
9-11
Calibration
Number of Active Database Settings
Latch on Trigger
Timer/Switch Value
Usage:
Can be useful when certain settings that are needed for one application are
not needed in another and processing time is at a premium.
Definition:
This value sets the number of configuration database settings (in
Database
Index
) that are active. If
Control Trigger
mode has been selected, this
setting is ignored.
Serial Cmd:
<
K226,
mode,
# active database settings
,latch on trigger,timer/switch
value,control trigger 1 status,control trigger 2 status,control trigger 3 status,
database cycles
>
Default:
1
Options:
Any number from 1 to 7.
Usage:
Useful when only one database index is required for the application.
Definition:
This feature is only used in
Control Trigger
mode. If enabled, the configuration
database settings selected at the start of a read cycle will remain active
during the entire read cycle. If
Latch on Trigger
is disabled, depending on
the control trigger inputs, the scanner’s optical settings can change
throughout the read cycle.
Note:
When
Control Trigger #3
is enabled,
Latch on Trigger
is also
enabled regardless of its previous setting.
Serial Cmd:
<
K226,
mode,# active database settings,
latch on trigger
,timer/switch
value,control trigger 1 status,control trigger 2 status,control trigger 3 status,
database cycles
>
Default:
Enabled
Options:
0 = Disabled
1 = Enabled
Usage:
Useful in slower applications where there is enough time to cycle through
the database index.
Definition:
When
Timer
mode is enabled,
Timer Value
is the time interval in which
database index settings are cycled.
Serial Cmd:
<
K226,
mode,# active database settings,latch on trigger,
timer/switch
value
,control trigger 1 status,control trigger 2 status,control trigger 3 status,
database cycles
>
Default:
5
Options:
0 to 255 (increments of 10ms)
Содержание MS-890
Страница 1: ...MS 890 Industrial Automation Scanner User Manual P N 84 000890 Rev B...
Страница 12: ...xii MS 890 Industrial Automation Scanner User Manual Statement of RoHS Compliance...
Страница 26: ...1 14 MS 890 Industrial Automation Scanner User Manual Save Configuration in ESP...
Страница 44: ...2 18 MS 890 Industrial Automation Scanner User Manual Send Receive Options...
Страница 94: ...4 24 MS 890 Industrial Automation Scanner User Manual Tracking Adjustment...
Страница 122: ...5 28 MS 890 Industrial Automation Scanner User Manual Autodiscriminate...
Страница 154: ...6 32 MS 890 Industrial Automation Scanner User Manual Quality Output...
Страница 168: ...7 14 MS 890 Industrial Automation Scanner User Manual Mismatch Replace...
Страница 202: ...9 22 MS 890 Industrial Automation Scanner User Manual Calibration by Embedded Menu...
Страница 212: ...10 10 MS 890 Industrial Automation Scanner User Manual Raster Laser by Embedded Menu...
Страница 240: ...12 22 MS 890 Industrial Automation Scanner User Manual Scanner Status Requests...
Страница 262: ...14 8 MS 890 Industrial Automation Scanner User Manual Wiring Box PCB with Connectors Wiring Box PCB with Connectors...
Страница 263: ...MS 890 Industrial Automation Scanner User Manual 14 9 Wiring Box Mounting Plate IB 890 Wiring Box Mounting Plate...
Страница 264: ...14 10 MS 890 Industrial Automation Scanner User Manual Mounting Plate...
Страница 308: ...A 44 MS 890 Industrial Automation Scanner User Manual Glossary of Terms...