Diagnostics
Warning Messages
Important Note: Warning Message Status
must be enabled before any warnings in this
menu can be displayed.
Warning Message Status
Laser High Status
When enabled, a message is transmitted whenever the laser current exceeds a factory-calibrated
reference value which cannot be altered. The message repeats once every 30 minutes
until the condition is corrected.
Usage:
These messages serve as a flag to service a scanner or as an early warning
that potential problems could arise. They are particularly useful in factories
that run constantly and can’t afford down time.
Definition:
Warning messages that relate to the environment and condition of the scanner
can be defined and set to activate specific outputs.
Note:
When enabled, the error condition will override all other operational
modes configured for the output.When enabled, laser current and
NOVRAM warning messages will be transmitted to the host or any active
port whenever the pre-defined conditions are met.
Function:
When enabled, warning messages will be transmitted to the host or any
active port.
Note:
This option must be enabled before any other warning messages can
be transmitted.
Serial Cmd:
<
K400,
warning message status
,laser high status,laser low status,
NOVRAM/reset warning status
>
Default:
Disabled
Options:
0 = Disabled
1 = Enabled
Usage:
Alerts the user to impending laser failure.
Definition:
Enables the
Laser High
message.
Serial Cmd:
<
K400,
warning message status,
laser high status
,laser low status,
NOVRAM/reset warning status
>
Default:
Enabled
Options:
0 = Disabled
1 = Enabled
Содержание MS-890
Страница 1: ...MS 890 Industrial Automation Scanner User Manual P N 84 000890 Rev B...
Страница 12: ...xii MS 890 Industrial Automation Scanner User Manual Statement of RoHS Compliance...
Страница 26: ...1 14 MS 890 Industrial Automation Scanner User Manual Save Configuration in ESP...
Страница 44: ...2 18 MS 890 Industrial Automation Scanner User Manual Send Receive Options...
Страница 94: ...4 24 MS 890 Industrial Automation Scanner User Manual Tracking Adjustment...
Страница 122: ...5 28 MS 890 Industrial Automation Scanner User Manual Autodiscriminate...
Страница 154: ...6 32 MS 890 Industrial Automation Scanner User Manual Quality Output...
Страница 168: ...7 14 MS 890 Industrial Automation Scanner User Manual Mismatch Replace...
Страница 202: ...9 22 MS 890 Industrial Automation Scanner User Manual Calibration by Embedded Menu...
Страница 212: ...10 10 MS 890 Industrial Automation Scanner User Manual Raster Laser by Embedded Menu...
Страница 240: ...12 22 MS 890 Industrial Automation Scanner User Manual Scanner Status Requests...
Страница 262: ...14 8 MS 890 Industrial Automation Scanner User Manual Wiring Box PCB with Connectors Wiring Box PCB with Connectors...
Страница 263: ...MS 890 Industrial Automation Scanner User Manual 14 9 Wiring Box Mounting Plate IB 890 Wiring Box Mounting Plate...
Страница 264: ...14 10 MS 890 Industrial Automation Scanner User Manual Mounting Plate...
Страница 308: ...A 44 MS 890 Industrial Automation Scanner User Manual Glossary of Terms...