5-22
MS-890 Industrial Automation Scanner
User Manual
PDF417
PDF417
Note:
Calibration does not function with PDF417 symbols. However, you can substitute a
Code 128 symbol with the same mil size as your PDF417. When you do this, enable
Code
128
and disable
Raster
scanning. After calibration, switch back to
PDF417
and
Raster
scanning.
PDF417 Status
Raster Sweeps Before Decode Attempt (PDF417)
Usage:
Used in applications where a large amount of information (over 32 characters)
needs to be encoded within a symbol, typically where the symbol is transported
from one facility to another. For example, an automobile assembly line might
use a single symbol with multiple fields of information that will be read at several
stations along the way, without reference to a database.
Definition:
A two-dimensional, multi-row (3 to 90), continuous, variable length symbology
that has high data capacity for storing up to 2700 numeric characters, 1,800
printable ASCII characters, or 1100 binary character per symbol. Each
symbol character consists of 4 bars and 4 spaces in a 17-module structure.
Serial Cmd:
<
K476,
status
,raster sweeps before decode attempt,fixed symbol length
status,fixed symbol length,decode at end of read>
Default:
Disabled
Options:
0 = Disabled
1 = Enabled
Usage:
Might be useful in dynamic applications where symbols are close together
and need to be decoded more quickly than the default setting allows.
Definition:
Specifies the number of raster sweeps the scanner will execute on PDF
symbols before decoding. A value of 0 effectively disables this feature,
which allows the decoder to make a “best guess” as to when enough symbol
words have been captured.
Serial Cmd:
<
K476,
status,
raster sweeps before decode attempt
,fixed symbol length
status,fixed symbol length,decode at end of read>
Default:
0
(disabled)
Options:
0 to 4
Содержание MS-890
Страница 1: ...MS 890 Industrial Automation Scanner User Manual P N 84 000890 Rev B...
Страница 12: ...xii MS 890 Industrial Automation Scanner User Manual Statement of RoHS Compliance...
Страница 26: ...1 14 MS 890 Industrial Automation Scanner User Manual Save Configuration in ESP...
Страница 44: ...2 18 MS 890 Industrial Automation Scanner User Manual Send Receive Options...
Страница 94: ...4 24 MS 890 Industrial Automation Scanner User Manual Tracking Adjustment...
Страница 122: ...5 28 MS 890 Industrial Automation Scanner User Manual Autodiscriminate...
Страница 154: ...6 32 MS 890 Industrial Automation Scanner User Manual Quality Output...
Страница 168: ...7 14 MS 890 Industrial Automation Scanner User Manual Mismatch Replace...
Страница 202: ...9 22 MS 890 Industrial Automation Scanner User Manual Calibration by Embedded Menu...
Страница 212: ...10 10 MS 890 Industrial Automation Scanner User Manual Raster Laser by Embedded Menu...
Страница 240: ...12 22 MS 890 Industrial Automation Scanner User Manual Scanner Status Requests...
Страница 262: ...14 8 MS 890 Industrial Automation Scanner User Manual Wiring Box PCB with Connectors Wiring Box PCB with Connectors...
Страница 263: ...MS 890 Industrial Automation Scanner User Manual 14 9 Wiring Box Mounting Plate IB 890 Wiring Box Mounting Plate...
Страница 264: ...14 10 MS 890 Industrial Automation Scanner User Manual Mounting Plate...
Страница 308: ...A 44 MS 890 Industrial Automation Scanner User Manual Glossary of Terms...