MS-890 Industrial Automation Scanner
User Manual
6-13
I/O Parameters
Serial Verification
Serial Command Echo Status
Important Note: ESP
will not function whenever this command is enabled.
Serial Command Beep Status
Important: ESP
will not function whenever this command is enabled.
Usage:
These commands are useful in removing any doubt about the scanner’s
acceptance and response to host configuration commands.
For example, if the current preamble is “
SOM
” and
<Kd1, START>
is
entered, the scanner will echo back
<Kd1, SOM>
since the attempted entry
“
START
” exceeds the four character limit for that command. Therefore it is
rejected and the existing “
SOM
” message is echoed back and remains the
preamble message.
Definition:
Allows the user to verify configuration command status.
Definition:
When enabled, a configuration command
received from the host is echoed back to
the host with the resultant settings.
Function:
If a command with multiple fields is processed, some of the fields may have
been processed properly while others were not. The changes will appear in
the string echoed back so that the user will know which fields did or did not
change.
Serial Cmd:
<
K701,
serial command echo status
,serial command beep status,control/
hex output>
Default:
Disabled
Options:
0 = Disabled
1 = Enabled
Usage:
Used to audibly verify the acceptance and validity of a command.
Definition:
Causes the scanner to beep once whenever a K command is entered to
indicate that the command was accepted and processed.
Function:
If an invalid command is entered, the scanner beeps 5 times to indicate an
invalid entry. However, this does not necessarily mean that all data fields
have been entered incorrectly. Only one bad field needs to be found in
order to activate the 5 beep response.
Serial Cmd:
<
K701,
serial command echo status,
serial command beep status
,control/
hex output
>
Default:
Disabled
Options:
0 = Disabled
1 = Enabled
Host
Scanner
Содержание MS-890
Страница 1: ...MS 890 Industrial Automation Scanner User Manual P N 84 000890 Rev B...
Страница 12: ...xii MS 890 Industrial Automation Scanner User Manual Statement of RoHS Compliance...
Страница 26: ...1 14 MS 890 Industrial Automation Scanner User Manual Save Configuration in ESP...
Страница 44: ...2 18 MS 890 Industrial Automation Scanner User Manual Send Receive Options...
Страница 94: ...4 24 MS 890 Industrial Automation Scanner User Manual Tracking Adjustment...
Страница 122: ...5 28 MS 890 Industrial Automation Scanner User Manual Autodiscriminate...
Страница 154: ...6 32 MS 890 Industrial Automation Scanner User Manual Quality Output...
Страница 168: ...7 14 MS 890 Industrial Automation Scanner User Manual Mismatch Replace...
Страница 202: ...9 22 MS 890 Industrial Automation Scanner User Manual Calibration by Embedded Menu...
Страница 212: ...10 10 MS 890 Industrial Automation Scanner User Manual Raster Laser by Embedded Menu...
Страница 240: ...12 22 MS 890 Industrial Automation Scanner User Manual Scanner Status Requests...
Страница 262: ...14 8 MS 890 Industrial Automation Scanner User Manual Wiring Box PCB with Connectors Wiring Box PCB with Connectors...
Страница 263: ...MS 890 Industrial Automation Scanner User Manual 14 9 Wiring Box Mounting Plate IB 890 Wiring Box Mounting Plate...
Страница 264: ...14 10 MS 890 Industrial Automation Scanner User Manual Mounting Plate...
Страница 308: ...A 44 MS 890 Industrial Automation Scanner User Manual Glossary of Terms...