5-12
MS-890 Industrial Automation Scanner
User Manual
Interleaved 2 of 5
Guard Bar (Interleaved 2 of 5)
Note:
Whenever
Guard Bar
is enabled, the presence of guard bars is required for decoding
to take place.
Range Mode (Interleaved 2 of 5)
Note:
Whenever
Guard Bar
is enabled, the presence of guard bars is required for decoding
to take place.
Usage:
Useful when I 2 of 5 multisymbols are enabled to prevent false data out-
put. This typically occurs with highly tilted or skewed symbols.
Definition:
A guard bar is a heavy bar, at least 2 times the width of the wide bar, surrounding
the printed I 2 of 5 symbol and helping to prevent false reads.
Serial Cmd:
<
K472,
status,check digit status,check digit output status,symbol length #1,
symbol length #2,
guard bar
,range mode>
Default:
Disabled
Options:
0 = Disabled
1 = Enabled
Definition:
When enabled, this feature causes symbol length # 1 and symbol length # 2
to form of a range of lengths that can be decoded.
For example, if symbol lengths of
10
and
6
are enabled, those are the
lengths that can be decoded. Note that either length can serve as the minimum
or maximum.
Serial Cmd:
<
K472,
status,check digit status,check digit output status,symbol length #1,
symbol length #2,guard bar,
range mode
>
Default:
Disabled
Options:
0 = Disabled
1 = Enabled
Содержание MS-890
Страница 1: ...MS 890 Industrial Automation Scanner User Manual P N 84 000890 Rev B...
Страница 12: ...xii MS 890 Industrial Automation Scanner User Manual Statement of RoHS Compliance...
Страница 26: ...1 14 MS 890 Industrial Automation Scanner User Manual Save Configuration in ESP...
Страница 44: ...2 18 MS 890 Industrial Automation Scanner User Manual Send Receive Options...
Страница 94: ...4 24 MS 890 Industrial Automation Scanner User Manual Tracking Adjustment...
Страница 122: ...5 28 MS 890 Industrial Automation Scanner User Manual Autodiscriminate...
Страница 154: ...6 32 MS 890 Industrial Automation Scanner User Manual Quality Output...
Страница 168: ...7 14 MS 890 Industrial Automation Scanner User Manual Mismatch Replace...
Страница 202: ...9 22 MS 890 Industrial Automation Scanner User Manual Calibration by Embedded Menu...
Страница 212: ...10 10 MS 890 Industrial Automation Scanner User Manual Raster Laser by Embedded Menu...
Страница 240: ...12 22 MS 890 Industrial Automation Scanner User Manual Scanner Status Requests...
Страница 262: ...14 8 MS 890 Industrial Automation Scanner User Manual Wiring Box PCB with Connectors Wiring Box PCB with Connectors...
Страница 263: ...MS 890 Industrial Automation Scanner User Manual 14 9 Wiring Box Mounting Plate IB 890 Wiring Box Mounting Plate...
Страница 264: ...14 10 MS 890 Industrial Automation Scanner User Manual Mounting Plate...
Страница 308: ...A 44 MS 890 Industrial Automation Scanner User Manual Glossary of Terms...