Symbologies
Codabar
Codabar Status
Start and Stop Match Status (Codabar)
Start and Stop Output Status
(Codabar)
Usage:
Used in photo-finishing and library applications. Used in some medical
applications at one time, but not typically used in newer applications.
Definition:
Codabar is a 16-character set (0 through 9, and the characters $, :, /, ., +,
and –) with start/stop codes and at least two distinctly different bar widths.
Serial Cmd:
<
K471,
status
,start and stop match status,start and stop output status,large
intercharacter gap,fixed symbol length status,symbol length,check character
type,check character output status>
Default:
Disabled
Options:
0 = Disabled
1 = Enabled
Usage:
Used to increase security of symbology.
Definition:
Requires the Codabar start and stop characters (a, b, c, or d) to match
before a valid read can occur.
Serial Cmd:
<
K471,
status
,
start and stop match status
,
start and stop output status,
large intercharacter gap,fixed symbol length status,symbol length,check
character type,check character output status
>
Default:
Enabled
Options:
0 = Disabled
1 = Enabled
Usage:
Used to verify matching.
Definition:
Causes the start and stop characters to be transmitted with symbol data.
Serial Cmd:
<
K471,
status,start and stop match status,
start and stop output status
,
large intercharacter gap,fixed symbol length status,symbol length,check
character type,check character status,check character output status>
Default:
Enabled
Options:
0 = Disabled
1 = Enabled
Содержание MS-890
Страница 1: ...MS 890 Industrial Automation Scanner User Manual P N 84 000890 Rev B...
Страница 12: ...xii MS 890 Industrial Automation Scanner User Manual Statement of RoHS Compliance...
Страница 26: ...1 14 MS 890 Industrial Automation Scanner User Manual Save Configuration in ESP...
Страница 44: ...2 18 MS 890 Industrial Automation Scanner User Manual Send Receive Options...
Страница 94: ...4 24 MS 890 Industrial Automation Scanner User Manual Tracking Adjustment...
Страница 122: ...5 28 MS 890 Industrial Automation Scanner User Manual Autodiscriminate...
Страница 154: ...6 32 MS 890 Industrial Automation Scanner User Manual Quality Output...
Страница 168: ...7 14 MS 890 Industrial Automation Scanner User Manual Mismatch Replace...
Страница 202: ...9 22 MS 890 Industrial Automation Scanner User Manual Calibration by Embedded Menu...
Страница 212: ...10 10 MS 890 Industrial Automation Scanner User Manual Raster Laser by Embedded Menu...
Страница 240: ...12 22 MS 890 Industrial Automation Scanner User Manual Scanner Status Requests...
Страница 262: ...14 8 MS 890 Industrial Automation Scanner User Manual Wiring Box PCB with Connectors Wiring Box PCB with Connectors...
Страница 263: ...MS 890 Industrial Automation Scanner User Manual 14 9 Wiring Box Mounting Plate IB 890 Wiring Box Mounting Plate...
Страница 264: ...14 10 MS 890 Industrial Automation Scanner User Manual Mounting Plate...
Страница 308: ...A 44 MS 890 Industrial Automation Scanner User Manual Glossary of Terms...