9-12
MS-890 Industrial Automation Scanner
User Manual
Optoelectric Control
Control Trigger 1 Status
Control Trigger 2 Status
Control Trigger 3 Status
Definition:
When
Control Trigger
mode is enabled,
Control Trigger #1
takes over
Input 1
(see
Input Mode
on page 6-19) and uses it to select an optoelectric
configuration from the configuration database. Active state is set by
Input 1
serial command.
Serial Cmd:
<
K226,
mode,# active database settings,latch on trigger,timer/switch
value,
control trigger 1 status
,control trigger 2 status,control trigger 3 status,
database cycles
>
Default:
Disabled
Options:
0 = Disabled
1 = Enabled
Definition:
New Master Pin
is used for
Control Trigger #2
. When enabled and
Mode
is set to
Control Trigger
, this input is used to select an optoelectric configuration
from
Configuration Database
.
Active State
is “Active Closed”.
Serial Cmd:
<
K226,
mode,# active database settings,latch on trigger,timer/switch
value,control trigger 1 status,
control trigger 2 status
,control trigger 3 status,
database cycles
>
Default:
Disabled
Options:
0 = Disabled
1 = Enabled
Definition:
Trigger Input
is used for
Control Trigger #3
. When enabled and
Mode
is
set to
Control Trigger
, this input is used to select an optoelectric configuration
from the
Configuration Database
.
Active State
is set by the
External
Trigger State
serial command.
Serial Cmd:
<
K226,
mode,# active database settings,latch on trigger,timer/switch
value,control trigger 1 status,control trigger 2 status,
control trigger 3 status
,
database cycles
>
Default:
Disabled
Options:
0 = Disabled
1 = Enabled
Содержание MS-890
Страница 1: ...MS 890 Industrial Automation Scanner User Manual P N 84 000890 Rev B...
Страница 12: ...xii MS 890 Industrial Automation Scanner User Manual Statement of RoHS Compliance...
Страница 26: ...1 14 MS 890 Industrial Automation Scanner User Manual Save Configuration in ESP...
Страница 44: ...2 18 MS 890 Industrial Automation Scanner User Manual Send Receive Options...
Страница 94: ...4 24 MS 890 Industrial Automation Scanner User Manual Tracking Adjustment...
Страница 122: ...5 28 MS 890 Industrial Automation Scanner User Manual Autodiscriminate...
Страница 154: ...6 32 MS 890 Industrial Automation Scanner User Manual Quality Output...
Страница 168: ...7 14 MS 890 Industrial Automation Scanner User Manual Mismatch Replace...
Страница 202: ...9 22 MS 890 Industrial Automation Scanner User Manual Calibration by Embedded Menu...
Страница 212: ...10 10 MS 890 Industrial Automation Scanner User Manual Raster Laser by Embedded Menu...
Страница 240: ...12 22 MS 890 Industrial Automation Scanner User Manual Scanner Status Requests...
Страница 262: ...14 8 MS 890 Industrial Automation Scanner User Manual Wiring Box PCB with Connectors Wiring Box PCB with Connectors...
Страница 263: ...MS 890 Industrial Automation Scanner User Manual 14 9 Wiring Box Mounting Plate IB 890 Wiring Box Mounting Plate...
Страница 264: ...14 10 MS 890 Industrial Automation Scanner User Manual Mounting Plate...
Страница 308: ...A 44 MS 890 Industrial Automation Scanner User Manual Glossary of Terms...