6-22
MS-890 Industrial Automation Scanner
User Manual
Configurable Output 1
Output State
Pulse Width
Output Mode
Pulse
This is the default mode of operation in which the programmable output is activated when
the
Output On
condition has been met and held active for the duration of the selected
pulse width.
Latch Mode 1
(Unlatch on Input 1 Pin)
In this mode the programmable output will be activated when the Output On condition is
met. It will stay active until the state of the Input 1 pin changes from inactive to active or
the proper mode is configured using the EZ Button.
Important:
To unlatch using the
Input 1
pin, the input status must be set to “Unlatch Out-
puts”. To unlatch using the
EZ Button
, the button status must be set to Unlatch Mode.
Latch Mode 2
(Unlatch Opposite Condition)
The programmable output is activated when the
Output On
condition has been met and
held active until the opposite condition selected under
Output On
has been met.
For example, if
No Read
is enabled under
Output On
, the programmable output will go
active on a No Read and remain active until the opposite condition, a Good Read, occurs.
Definition:
Sets the active electrical state of the discrete output.
Serial Cmd:
<
K810,
output on,
output state
,pulse width,output mode
>
Default:
Negative
Options:
0 = Negative
1 = Positive
Definition:
Sets the time in 10 ms increments that the discrete output remains active.
Serial Cmd:
<
K810,
output on,output state,
pulse width
,output mode
>
Default:
50
Options:
1 to 65535 (Divide the number entered on the command line by 100 for time
in seconds)
Definition:
Sets the condition in which the discrete output is de-activated.
Serial Cmd:
<
K810,
output on,output state,pulse width,
output mode
>
Default:
Pulse
Options:
0 = Pulse
1 = Latch Mode 1
2 = Latch Mode 2
3 = Latch Mode 3
Содержание MS-890
Страница 1: ...MS 890 Industrial Automation Scanner User Manual P N 84 000890 Rev B...
Страница 12: ...xii MS 890 Industrial Automation Scanner User Manual Statement of RoHS Compliance...
Страница 26: ...1 14 MS 890 Industrial Automation Scanner User Manual Save Configuration in ESP...
Страница 44: ...2 18 MS 890 Industrial Automation Scanner User Manual Send Receive Options...
Страница 94: ...4 24 MS 890 Industrial Automation Scanner User Manual Tracking Adjustment...
Страница 122: ...5 28 MS 890 Industrial Automation Scanner User Manual Autodiscriminate...
Страница 154: ...6 32 MS 890 Industrial Automation Scanner User Manual Quality Output...
Страница 168: ...7 14 MS 890 Industrial Automation Scanner User Manual Mismatch Replace...
Страница 202: ...9 22 MS 890 Industrial Automation Scanner User Manual Calibration by Embedded Menu...
Страница 212: ...10 10 MS 890 Industrial Automation Scanner User Manual Raster Laser by Embedded Menu...
Страница 240: ...12 22 MS 890 Industrial Automation Scanner User Manual Scanner Status Requests...
Страница 262: ...14 8 MS 890 Industrial Automation Scanner User Manual Wiring Box PCB with Connectors Wiring Box PCB with Connectors...
Страница 263: ...MS 890 Industrial Automation Scanner User Manual 14 9 Wiring Box Mounting Plate IB 890 Wiring Box Mounting Plate...
Страница 264: ...14 10 MS 890 Industrial Automation Scanner User Manual Mounting Plate...
Страница 308: ...A 44 MS 890 Industrial Automation Scanner User Manual Glossary of Terms...