MS-890 Industrial Automation Scanner
User Manual
5-11
Symbologies
Symbol Length #1 (Interleaved 2 of 5)
Symbol Length #2 (Interleaved 2 of 5)
Usage:
With I–2/5, two symbol lengths can be defined. When using only one symbol
length in an application, setting
Symbol Length #2
to 0 (zero) to ensure
data integrity is recommended.
Definition:
Allows user to define the symbol length. Because I–2/5 is a continuous
symbology, it is prone to substitution errors. Hence, a symbol length must be
defined and a symbol must contain an even number of digits.
Note
: If start, stop or check digits are used, they are not included in the
symbol length count.
Serial Cmd:
<
K472,
status,check digit status,check digit output status,
symbol length
#1
,symbol length #2,guard bar status,range mode>
Default:
10
Options:
0 to 128, even
Note:
Since I 2/5 characters are paired, symbol length must be set to an
even number. If
Check Digit
is enabled, add 2 to your symbol length. For
example, if your symbol is 10 characters plus a check digit, then enable
Symbol Length
for 12.
Note:
Typically, when printing an I 2/5 symbol with an odd number of digits, a
0 will be added as the first character.Note: If both Symbol Length #1 and
Symbol Length #2 are set to
0
, then I–2 of 5 will be variable.
Usage:
If using a second symbol, a zero or any even symbol length from 2 to 64
may be specified. If not using a second symbol, set
Symbol Length #2
to
0
to ensure data integrity.
Definition:
Allows user to define a second symbol length for I–2/5.
Serial Cmd:
<
K472,
status,check digit status,check digit output status,symbol length
#1,
symbol length #2
,guard bar status,range mode>
Default:
6
Options:
0 to 128, even
Since I 2/5 characters are paired, symbol length must be set to an even
number. If
Check Digit
is enabled, add 2 to your symbol length. For
example, if your symbol is 10 characters plus a check digit, then enable
Symbol Length
for 12.
Note:
Typically, when printing an I 2/5 symbol with an odd number of digits,
a 0 will be added as the first character.
Note:
If both
Symbol Length #1
and
Symbol Length #2
are set to
0
, then
I–2 of 5 will be variable.
Содержание MS-890
Страница 1: ...MS 890 Industrial Automation Scanner User Manual P N 84 000890 Rev B...
Страница 12: ...xii MS 890 Industrial Automation Scanner User Manual Statement of RoHS Compliance...
Страница 26: ...1 14 MS 890 Industrial Automation Scanner User Manual Save Configuration in ESP...
Страница 44: ...2 18 MS 890 Industrial Automation Scanner User Manual Send Receive Options...
Страница 94: ...4 24 MS 890 Industrial Automation Scanner User Manual Tracking Adjustment...
Страница 122: ...5 28 MS 890 Industrial Automation Scanner User Manual Autodiscriminate...
Страница 154: ...6 32 MS 890 Industrial Automation Scanner User Manual Quality Output...
Страница 168: ...7 14 MS 890 Industrial Automation Scanner User Manual Mismatch Replace...
Страница 202: ...9 22 MS 890 Industrial Automation Scanner User Manual Calibration by Embedded Menu...
Страница 212: ...10 10 MS 890 Industrial Automation Scanner User Manual Raster Laser by Embedded Menu...
Страница 240: ...12 22 MS 890 Industrial Automation Scanner User Manual Scanner Status Requests...
Страница 262: ...14 8 MS 890 Industrial Automation Scanner User Manual Wiring Box PCB with Connectors Wiring Box PCB with Connectors...
Страница 263: ...MS 890 Industrial Automation Scanner User Manual 14 9 Wiring Box Mounting Plate IB 890 Wiring Box Mounting Plate...
Страница 264: ...14 10 MS 890 Industrial Automation Scanner User Manual Mounting Plate...
Страница 308: ...A 44 MS 890 Industrial Automation Scanner User Manual Glossary of Terms...