7-6
MS-890 Industrial Automation Scanner
User Manual
Matchcode Type
Match Start Position
Note:
Match Start Position
must be set to
1
or greater to enable this feature.
A
0
setting will disable this feature.
Match Length
Usage:
Match Start Position
is useful in defining specific portions of a symbol for
comparisons. For example, if a symbol contains a part number, manufacturing
date, and lot code info but the user is only interested in the part number
information,
Match Start Position
can be set to only sort on the part number
and ignore the rest of the characters.
Definition:
Match Start Position
determines the portions of symbols that will be
matched by defining the first character in the symbol (from left to right) that
will be compared with those of the master symbol, when
Matchcode Type
is set to
Enabled
or
Sequential
.
Function:
For example, if
Match Start Position
is set to 3, the first 2 characters read
in the symbol will be ignored and only the 3rd and subsequent characters to
the right will be compared, up to the number of characters specified by
Match Length
.
Serial Cmd:
<
K223,
matchcode type,sequential matching,
match start position
,
match length,wild card character,sequence on No Read,sequence on mismatch
>
Default:
0
Options:
0 to maximum length allowed for master symbol
Definition:
Defines the length of the character string that will be compared with that of
the master symbol when
Match Start Position
is set to
1
or greater. When
Match Start Position
is set to
0
, no comparison will occur.
Usage:
For example, if
Match Length
is set to
6
in a 10 character symbol, and
Match Start Position
is set for
2
, only the 2nd through 7th characters (from
left to right) will be compared.
Serial Cmd:
<
K223,
matchcode type,sequential matching,match start position,
match length
,wild card character,sequence on No Read,sequence on mismatch
>
Default:
1
Options:
1 to 2710
Содержание MS-890
Страница 1: ...MS 890 Industrial Automation Scanner User Manual P N 84 000890 Rev B...
Страница 12: ...xii MS 890 Industrial Automation Scanner User Manual Statement of RoHS Compliance...
Страница 26: ...1 14 MS 890 Industrial Automation Scanner User Manual Save Configuration in ESP...
Страница 44: ...2 18 MS 890 Industrial Automation Scanner User Manual Send Receive Options...
Страница 94: ...4 24 MS 890 Industrial Automation Scanner User Manual Tracking Adjustment...
Страница 122: ...5 28 MS 890 Industrial Automation Scanner User Manual Autodiscriminate...
Страница 154: ...6 32 MS 890 Industrial Automation Scanner User Manual Quality Output...
Страница 168: ...7 14 MS 890 Industrial Automation Scanner User Manual Mismatch Replace...
Страница 202: ...9 22 MS 890 Industrial Automation Scanner User Manual Calibration by Embedded Menu...
Страница 212: ...10 10 MS 890 Industrial Automation Scanner User Manual Raster Laser by Embedded Menu...
Страница 240: ...12 22 MS 890 Industrial Automation Scanner User Manual Scanner Status Requests...
Страница 262: ...14 8 MS 890 Industrial Automation Scanner User Manual Wiring Box PCB with Connectors Wiring Box PCB with Connectors...
Страница 263: ...MS 890 Industrial Automation Scanner User Manual 14 9 Wiring Box Mounting Plate IB 890 Wiring Box Mounting Plate...
Страница 264: ...14 10 MS 890 Industrial Automation Scanner User Manual Mounting Plate...
Страница 308: ...A 44 MS 890 Industrial Automation Scanner User Manual Glossary of Terms...